Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Supplementary Diagnostic Landmarks of Left Ventricular Non-Compaction on Magnetic Resonance Imaging (CROSBI ID 246494)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Boban, Marko ; Pesa, Vladimir ; Beck, Natko ; Manola, Sime ; Žulj, Marinko ; Rotim, Ante ; Včev, Aleksandar Supplementary Diagnostic Landmarks of Left Ventricular Non-Compaction on Magnetic Resonance Imaging // Yonsei medical journal, 59 (2018), 1; 63-71. doi: 10.3349/ymj.2018.59.1.63

Podaci o odgovornosti

Boban, Marko ; Pesa, Vladimir ; Beck, Natko ; Manola, Sime ; Žulj, Marinko ; Rotim, Ante ; Včev, Aleksandar

hrvatski

Supplementary Diagnostic Landmarks of Left Ventricular Non-Compaction on Magnetic Resonance Imaging

Diagnostic criteria for left ventricular non-compaction (LVNC) are still a matter of dispute. The aim of our present study was to test the diagnostic value of two novel diagnostic cardiac magnetic resonance (CMR) parameters: proof of non-compact (NC) myocardium blood flow using T2 sequences and changes in geometry of the left ventricle. The study included cases with LVNC and controls, from a data base formed in a period of 3.5 years (n=1890 exams), in which CMR protocol included T2 sequences. Measurement of perpendicular maximal and minimal end diastolic dimensions in the region with NC myocardium from short axis plane was recorded, and calculated as a ratio (MaxMinEDDR), while flow through trabecula was proven by intracavital T2-weighted hyperintensity (ICT2HI). LVNC diagnosis met the following three criteria: thickening of compact (C) layer, NC:C>2.3:1 and NC>20%LV. The study included 200 patients ; 71 with LVNC (35.5% ; i.e., 3.76% of CMRs) and 129 (64.5%) controls. MaxMinEDDR in patients with LVNC was significantly different from that in controls (1.17±0.08 vs. 1.06±0.04, respectively ; p<0.001). MaxMinEDDR >1.10 had sensitivity of 91.6% [95% confidence intervals (CI) 82.5-96.8], specificity of 85.3% (95% CI 78.0-90.0), and area under curve (AUC) 0.919 (95% CI 0.872-0.953 ; p<0.001) for LVNC. Existence of ICT2HI had sensitivity of 100.0% (95% CI 94.9-100.0), specificity of 91.5% (95% CI 85.3-95.7), and AUC 0.957 (95% CI 0.919-0.981 ; p<0.001) for LVNC. Two additional diagnostic parameters for LVNC were identified in this study. ICT2HI and geometric eccentricity of the ventricle both had relatively high sensitivity and specificity for diagnosing LVNC.

Left ventricle non-compaction ; cardiac magnetic resonance imaging ; diagnostic criteria ; T2-sequences ; maximal to minimal end diastolic diameters ratio

nije evidentirano

engleski

Supplementary Diagnostic Landmarks of Left Ventricular Non-Compaction on Magnetic Resonance Imaging

nije evidentirano

Left ventricle non-compaction ; cardiac magnetic resonance imaging ; diagnostic criteria ; T2-sequences ; maximal to minimal end diastolic diameters ratio

nije evidentirano

Podaci o izdanju

59 (1)

2018.

63-71

objavljeno

0513-5796

1976-2437

10.3349/ymj.2018.59.1.63

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost