Improvement of the Cogeneration Plant Economy by Using Heat Accumulator (CROSBI ID 494623)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Bogdan, Željko ; Kopjar, Damir
engleski
Improvement of the Cogeneration Plant Economy by Using Heat Accumulator
The optimisation code ACOM is used with purpose of assessing influence of the district heat accumulator on the EL-TO Zagreb cogeneration plant economic performance. The plant supplies hot water for district heating, process steam for industry and electric power. It is possible to achieve economic benefits by charging the accumulator during day time when electricity price is high and by realising district heat during cheap night hours when other parts of equipment may be shut down. The consequences of this strategy are the decrease of total annual electricity production and fuel consumption whereby the savings are achieved of some 1.8 mil Euro/a with reduction of CO2 emission for about 23, 000 t/a or 6.4 % and SOx for about 200 t/a or 16.9 %.
cogeneration plant; heat accumulator; economic performance
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
97-104-x.
2003.
objavljeno
Podaci o matičnoj publikaciji
Sustainable Development of Energy, Water and Environment Systems
Guzović, Zvonimir
Zagreb: Fakultet strojarstva i brodogradnje Sveučilišta u Zagrebu
Podaci o skupu
Dubrovnik Conference on Sustainable Development of Energy, Water and Environment Systems
predavanje
15.06.2003-20.06.2003
Dubrovnik, Hrvatska