Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

SO3 Reduction in the 210 MW Oil-fired Power Plant Sisak (CROSBI ID 474812)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Schneider, Daniel Rolph ; Duić, Neven ; Bogdan, Željko SO3 Reduction in the 210 MW Oil-fired Power Plant Sisak // Proc. of the 5th European Conference on Industrial Furnaces and Boilers / Leuckel, Wolfgang (ur.). Porto: INFUB, 2000

Podaci o odgovornosti

Schneider, Daniel Rolph ; Duić, Neven ; Bogdan, Željko

engleski

SO3 Reduction in the 210 MW Oil-fired Power Plant Sisak

Various impacts of the combustion process parameters and burner design characteristics on the SO3 generation in the steam generator furnace of the 210 MW oil-fired Power Plant Sisak have been studied by using 3-D mathematical modelling. Problems of the Power Plant Sisak, which burns heavy-oil fuel with 2-3% sulphur and exhibits flue gas temperatures of 135-140 oC at the exit of the regenerative Ljungstrom air-heater, are related to severe low temperature corrosion and environmental pollution. Different parameters were varied: combustion air excess ratio, spray angle of fuel injection, number of openings on the steam-pressure atomiser nozzle and fuel droplet size. By using the FLUENT(TM) software package for simulation of the oil combustion process in the furnace, relatively reliable results have been obtained which favourably could be compared with scarce existing experimental data. This means that trends of influential parameters have been well predicted rather than absolute values of the same parameters. The results of the simulation showed that the excess combustion air of 1.07-1.10 could not be decreased without a reconstruction of combustors because of soot appearance and increased CO concentration. By increasing the number of nozzle openings and the fuel atomising steam pressure i.e. by decreasing the fuel droplet size, the excess air has been decreased to 1.035, which represents the upper limit of desired result. Thereby the average SO3 concentration in flue gases was about 25-30 ppm. The variation of fuel spray angle has been found not to have any significant influence on SO3 and CO concentrations. By major reconstruction at the air inlet and air swirl generator and by modification of the combustion control better results could be expected which would maximally reduce problems with low temperature corrosion and environment pollution.

SO3 reduction; low temperature corrosion; heavy-oil fuel combustion; mathematical modelling; burner optimisation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

2000.

objavljeno

Podaci o matičnoj publikaciji

Proc. of the 5th European Conference on Industrial Furnaces and Boilers

Leuckel, Wolfgang

Porto: INFUB

Podaci o skupu

5th European Conference on Industrial Furnaces and Boilers

poster

11.04.2000-14.04.2000

Porto, Portugal

Povezanost rada

Strojarstvo