Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Applicability of bovine tibia as a model in research on various osteosynthesis techniques (CROSBI ID 162049)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Šišljagić, Vladimir ; Jovanović, Savo ; Mrčela, Tomislav ; Nikolić, Vasilije ; Radić, Radivoje ; Wertheimer, Vjekoslav ; Kovač, Tanja ; Mrčela, Milanka Applicability of bovine tibia as a model in research on various osteosynthesis techniques // Periodicum biologorum, 112 (2010), 59-62

Podaci o odgovornosti

Šišljagić, Vladimir ; Jovanović, Savo ; Mrčela, Tomislav ; Nikolić, Vasilije ; Radić, Radivoje ; Wertheimer, Vjekoslav ; Kovač, Tanja ; Mrčela, Milanka

engleski

Applicability of bovine tibia as a model in research on various osteosynthesis techniques

Background and purpose: The main problem in experimental research in traumalology and orthopedics is unavailability of a large number of samples of human origin. In this research, standard and modified osteo-syntheses were performed on bovine tibia to determine whether bovine tibia can be used as a model in biomechanical research on two or more methods of osteosynthesis. Materials and methods: Investigations were carried out on six preparations of cadaveric human tibia and on six preparations of bovine tibia with the use of device for static and dynamic research on long bone model. The bones were artificially broken and then osteosynthesis was performed on them in two ways: applying the standard method and the modified method with bone cement. The aim of these investigations was to determine the size of the axial force and torsion moment that can be exerted to apply static and dynamic loading on the macerated cadaveric tibia and bovine tibia without breaking the bone or causing its permanent deformation. Results: Investigations conducted on preparations of bovine tibia and cadaveric human tibia showed that there was not even minimal deformation of the bovine tibia in both standard and modified osteosynthesis. There was no shift in torsion angle at all with all three values of torsion moment applied in these investigations. This result was obtained in both standard and modified osteosynthesis. The results showed that in both bovine and human preparations the loosening occurred sooner when standard osteosynthesis was applied. Conclusion: In conclusion, the bovine bone has good potential for use as material for biomechanical experiments.

osteosynthesis; bovine tibia; biomechanics

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

112

2010.

59-62

objavljeno

0031-5362

Povezanost rada

Temeljne medicinske znanosti

Poveznice
Indeksiranost