Mass Flow Meter Analysis for Reliable Measuring (CROSBI ID 183626)
Prilog u časopisu | izvorni znanstveni rad
Podaci o odgovornosti
Kupanovac, Tihomir ; Špoljarić, Željko ; Valter, Zdravko
engleski
Mass Flow Meter Analysis for Reliable Measuring
The aim of this paper is to show how to analyze and correctly chose measuring device specially applied on mass flow meter based on Coriolis principle. In the beginning short description of Coriolis based mass flow meter is given. Furthermore, comparison analysis of two flow meters shows where are the problems of wrongly applied method in slurry fluid measurement in production of powder detergents plant. Analysis is made using RS Logix 500 program. In given diagrams which shows causes of wrong measurements and position of mass flow device the few malfunctions are determinated. Finally, using comparison measurement with new mass flow meter shows that measurement method is applicable for slurry fluids which are specially problematic and complex for measuring.
mass flow; Coriolis principle; analysis; problematic; slurry fluid
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
Vol.3 (No.1)
2012.
25-30
objavljeno
1847-6996
1847-7003
Povezanost rada
Elektrotehnika