The seasonal dependence of PM10 Equivalence testing (CROSBI ID 602034)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Bešlić, Ivan ; Šega, Krešimir ; Davila, Silvije The seasonal dependence of PM10 Equivalence testing // Proceedings of the 16th IUAPPA World Clean Air Congress - "Many Nations - One Atmosphere: Plotting the Path to Sustainability". Cape Town: National Association for Clean Air, 2013. str. 58-x

Podaci o odgovornosti

Bešlić, Ivan ; Šega, Krešimir ; Davila, Silvije

engleski

The seasonal dependence of PM10 Equivalence testing

The equivalence testing of automatic analysers and non-referent samplers for PM10 particle fractions with referent samplers is required according to European Directive 2008/50/EC. The aim of this article was to assess the annual and seasonal correction functions for the ESM Andersen FH-61 IR automatic analyser and for the HVS Digitel DH-80 nonreferent sampler. For the purposes of equivalence testing, the LVS Sven Leckel SEQ referent sampler was used. Furthermore, the aim of this investigation was to determine the influence of equivalence testing on statistical parameters for air quality assessment. The non-referent devices did not satisfy the measuring uncertainty requirements (U < 25 %) for both yearly and seasonal data sets. The corrected results satisfied the measuring uncertainty requirements, except for the autumn data sets and the yearly data set obtained by the automatic analyser. The statistical parameters for air quality assessment obtained by non-referent devices were significantly lower than the parameters obtained by the referent sampler. The correction functions of non-referent devices significantly differed among each other. This analysis points out the necessity of seasonal corrections of PM10 concentrations obtained by non-referent devices.

PM10; orthogonal regression; correction function; expanded measuring uncertainty

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

58-x.

2013.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the 16th IUAPPA World Clean Air Congress - "Many Nations - One Atmosphere: Plotting the Path to Sustainability"

Cape Town: National Association for Clean Air

978-0-620-58319-0

Podaci o skupu

16th IUAPPA World Clean Air Congress - "Many Nations - One Atmosphere: Plotting the Path to Sustainability"

predavanje

29.09.2013-04.10.2013

Cape Town, Južnoafrička Republika

Povezanost rada

Fizika, Javno zdravstvo i zdravstvena zaštita