Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Comparative Performance of Four Methods for High-throughput Glycosylation Analysis of Immunoglobulin G in Genetic and Epidemiological Research (CROSBI ID 208494)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Huffman, Jennifer E. ; Pučić-Baković, Maja ; Klarić, Lucija ; Hennig, Rene ; Selman, Maurice H. ; Vučković, Frano ; Novokmet, Mislav ; Krištić, Jasminka ; Borowiak, Matthias, Muth, Thilo ; Polašek, Ozren et al. Comparative Performance of Four Methods for High-throughput Glycosylation Analysis of Immunoglobulin G in Genetic and Epidemiological Research // Molecular & cellular proteomics, 13 (2014), 1598-1610. doi: 10.1074/mcp.M113.037465

Podaci o odgovornosti

Huffman, Jennifer E. ; Pučić-Baković, Maja ; Klarić, Lucija ; Hennig, Rene ; Selman, Maurice H. ; Vučković, Frano ; Novokmet, Mislav ; Krištić, Jasminka ; Borowiak, Matthias, Muth, Thilo ; Polašek, Ozren ; Razdorov, Genadij ; Gornik, Olga ; Plomp, Rosina ; Theodoratou, Evropi ; Wright, Alan F. ; Rudan, Igor ; Hayward, Caroline ; Campbell Harry ; Deelder, Andre M. ; Reichl, Udo ; Aulchenko Yurii S. ; Rapp, Erdmann ; Wuhrer, Manfred ; Lauc, Gordan

engleski

Comparative Performance of Four Methods for High-throughput Glycosylation Analysis of Immunoglobulin G in Genetic and Epidemiological Research

The biological and clinical relevance of glycosylation is becoming increasingly recognized, leading to a growing interest in large-scale clinical and population-based studies. In the past few years, several methods for high-throughput analysis of glycans have been developed, but thorough validation and standardization of these methods is required before significant resources are invested in large-scale studies. In this study, we compared liquid chromatography, capillary gel electrophoresis, and two MS methods for quantitative profiling of N-glycosylation of IgG in the same data set of 1201 individuals. To evaluate the accuracy of the four methods we then performed analysis of association with genetic polymorphisms and age. Chromatographic methods with either fluorescent or MS-detection yielded slightly stronger associations than MS-only and multiplexed capillary gel electrophoresis, but at the expense of lower levels of throughput. Advantages and disadvantages of each method were identified, which should inform the selection of the most appropriate method in future studies.

IgG ; glycosylation ; UPLC ; CGE-LIF ; MALDI-TOF MS ; LC-MS

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

13

2014.

1598-1610

objavljeno

1535-9476

10.1074/mcp.M113.037465

Povezanost rada

Biologija

Poveznice
Indeksiranost