Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

CARBON MASS CONCENTRATIONS IN SOUTHERN ZAGREB DURING A FIVE-YEAR PERIOD (CROSBI ID 628850)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Godec, Ranka ; Šega, Krešimir ; Bešlić, Ivan ; Davila, Silvije ; CARBON MASS CONCENTRATIONS IN SOUTHERN ZAGREB DURING A FIVE-YEAR PERIOD // WeBIOPATR2015 THE FIFTH INTERNATIONAL WeBIOPATR WORKSHOP & CONFERENCE PARTICULATE MATTER: RESEARCH AND MANAGEMENT / Jovašević-Stojanović, Milena ; Bartoňová, Alena (ur.). Beograd: Public Health Institute of Belgrade, 2015. str. 36-36

Podaci o odgovornosti

Godec, Ranka ; Šega, Krešimir ; Bešlić, Ivan ; Davila, Silvije ;

engleski

CARBON MASS CONCENTRATIONS IN SOUTHERN ZAGREB DURING A FIVE-YEAR PERIOD

The purpose of this study was to see how the mass concentrations of elemental and organic carbon change during the seasons and whether they change over a longer period of measurement. The sampling station was located on the roof of the Siget Medical Centre in the southern part of Zagreb. This site, defined as an urban monitoring station, is burdened with heavy traffic and is close to offices and schools. Samples of PM10 particle fraction were collected from approximately 55 m3 of air on quartz fiber filters (Pallflex Tissuequartz 2500QAT UP, Pall Life Sciences), pre-fired at 900 °C for three hours. Sven Leckel LVS3 (Sven Leck Inginierbüro, Berlin, Germany) reference samplers were used for sample collection and PM10 mass concentrations were determined gravimetrically according to the HRN EN 12341 standard. Organic carbon (OC) and elemental carbon (EC) in PM10 fraction were determined by the thermal-optical transmittance method (TOT), using a Carbon Aerosol Analyzer (Sunset Laboratory Inc.) with a FID flame ionization detector following a NIOSH-like protocol called Quartz (Birch and Cary, 1996, Quincey et al., 2009, Godec et al., 2012). Sampling was conducted from 2 January 2009 to 31 December 2013. A slight negative trend of PM10 mass concentrations was noticed during the five-year period. Mean mass concentrations of EC and OC for all five years were 2.34 µg m-3 and 11.4 µg m-3, respectively. Yearly mean mass concentrations of OC followed the sequence: 2010 > 2009 > 2012 >2013 > 2011. The lowest daily measured concentration of EC was recorded in 2012 and was 0.26 µg m-3. The OC/EC ratio for all five years was 5.2, which indicated a presence of secondary OC in this part of Zagreb. The lowest daily OC/EC ratio was recorded in 2009 and was 1.1, which indicated only the presence of primary OC in the air during that day. Mass concentrations of PM10 and OC as well as OC/EC ratio followed the sequence: winter > autumn > spring > summer. The highest EC mass concentration was recorded during autumn, while the lowest during spring. Average EC and OC contributions to PM10 mass were 7 % and 26 %, respectively. The highest OC contribution to PM10 mass was recorded during autumn, while the lowest EC contribution to PM10 mass was recorded during winter.

EC; OC; OC/EC ratio; PM10; TOT-method

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

36-36.

2015.

objavljeno

Podaci o matičnoj publikaciji

WeBIOPATR2015 THE FIFTH INTERNATIONAL WeBIOPATR WORKSHOP & CONFERENCE PARTICULATE MATTER: RESEARCH AND MANAGEMENT

Jovašević-Stojanović, Milena ; Bartoňová, Alena

Beograd: Public Health Institute of Belgrade

978-86-83069-42-2

Podaci o skupu

WeBIOPATR 2015 THE FIFTH INTERNATIONAL WeBIOPATR WORKSHOP & CONFERENCE PARTICULATE MATTER: RESEARCH AND MANAGEMENT

predavanje

14.10.2015-16.10.2015

Beograd, Srbija

Povezanost rada

Kemija, Javno zdravstvo i zdravstvena zaštita

Poveznice