Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Segmentation of the foveal microvasculature using deep learning networks (CROSBI ID 230284)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Prentašić, Pavle ; Heisler, Morgan ; Mammo, Zaid ; Lee, Sieun ; Merkur, Andrew ; Navajas, Eduardo ; Faisal Beg, Mirza ; Šarunić, Marinko ; Lončarić , Sven Segmentation of the foveal microvasculature using deep learning networks // Journal of biomedical optics, 21 (2016), 7; 075008-1-075008-7. doi: 10.1117/1.JBO.21.7.075008

Podaci o odgovornosti

Prentašić, Pavle ; Heisler, Morgan ; Mammo, Zaid ; Lee, Sieun ; Merkur, Andrew ; Navajas, Eduardo ; Faisal Beg, Mirza ; Šarunić, Marinko ; Lončarić , Sven

engleski

Segmentation of the foveal microvasculature using deep learning networks

Accurate segmentation of the retinal microvasculature is a critical step in the quantitative analysis of the retinal circulation, which can be an important marker in evaluating the severity of retinal diseases. As manual segmentation remains the gold standard for segmentation of optical coherence tomography angiography (OCT-A) images, we present a method for automating the segmentation of OCT-A images using deep neural networks (DNNs). Eighty OCT-A images of the foveal region in 12 eyes from 6 healthy volunteers were acquired using a prototype OCT-A system and subsequently manually segmented. The automated segmentation of the blood vessels in the OCT-A images was then performed by classifying each pixel into vessel or nonvessel class using deep convolutional neural networks. When the automated results were compared against the manual segmentation results, a maximum mean accuracy of 0.83 was obtained. When the automated results were compared with inter and intrarater accuracies, the automated results were shown to be comparable to the human raters suggesting that segmentation using DNNs is comparable to a second manual rater. As manually segmenting the retinal microvasculature is a tedious task, having a reliable automated output such as automated segmentation by DNNs, is an important step in creating an automated output.

image segmentation ; neural networks ; optical coherence tomography angiography ; ophthalmology.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

21 (7)

2016.

075008-1-075008-7

objavljeno

1083-3668

10.1117/1.JBO.21.7.075008

Povezanost rada

Računarstvo

Poveznice
Indeksiranost