Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Optimization of parameters for histamine detection in fish muscle extracts by surfaceenhanced Raman spectroscopy using silver colloid SERS substrates (CROSBI ID 235589)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Janči, Tibor ; Mikac, Lara ; Ivanda, Mile ; Marušić Radovčić, Nives ; Medić, Helga ; Vidaček, Sanja Optimization of parameters for histamine detection in fish muscle extracts by surfaceenhanced Raman spectroscopy using silver colloid SERS substrates // Journal of Raman spectroscopy, 48 (2017), 1; 64-72. doi: 10.1002/jrs.4991

Podaci o odgovornosti

Janči, Tibor ; Mikac, Lara ; Ivanda, Mile ; Marušić Radovčić, Nives ; Medić, Helga ; Vidaček, Sanja

engleski

Optimization of parameters for histamine detection in fish muscle extracts by surfaceenhanced Raman spectroscopy using silver colloid SERS substrates

This study was focused on investigating possibility of histamine detection in fish by Surface Enhanced Raman Spectroscopy. Four different silver colloids were used as SERS substrates in combination with different aggregation agents. Excitation wavelength, aggregating agent concentration and time of data acquisition have been optimized in order to obtain maximum enhancement of histamine signals. Best results were obtained with 514.5 nm excitation wavelength, citrate reduced silver colloid and 0.23 mol/L NaBH4 as aggregating agents enabling detection of histamine in water solutions at concentration of 5×10-6 mol/L. Calibration curve was constructed by applying Langmuir adsorption isotherm formula to fit the experimental data. Due to interferences from other components, histamine was detected at concentration of 1×10-4 mol/L (111.2 mg/kg of fish) in fish muscle extracts. Although further improvements are needed to achieve detection and quantification of histamine at legislative set limits these results show a potential for development of new histamine detection method in fish and fish products.

surface-enhanced Raman spectroscopy ; silver colloid ; histamine ; fish

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

48 (1)

2017.

64-72

objavljeno

0377-0486

10.1002/jrs.4991

Povezanost rada

nije evidentirano

Poveznice
Indeksiranost