Frequency response and harmonic distortion testing of inductive voltage transformer used for power quality measurements (CROSBI ID 647613)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Filipović-Grčić, Dalibor ; Filipović-Grčić, Božidar ; Krajtner, Danijel Frequency response and harmonic distortion testing of inductive voltage transformer used for power quality measurements // 4th International Colloquium "Transformer Research and Asset Management", Pula, Croatia, May 10 – 12, 2017. Zagreb: CIGRÉ, 2017. str. 1-9

Podaci o odgovornosti

Filipović-Grčić, Dalibor ; Filipović-Grčić, Božidar ; Krajtner, Danijel

engleski

Frequency response and harmonic distortion testing of inductive voltage transformer used for power quality measurements

International standards related to power quality measurements define methods and accuracies for the measuring instruments, but do not specify the accuracy of instrument transformers. Therefore, it is not possible to specify an overall accuracy for such measurements. Inductive voltage transformers (IVTs) which are used for power quality measurements should be tested to determine the ratio correction factors (RCFs) and phase angle errors at higher frequencies. In this paper, harmonic distortion and frequency response tests are performed to determine the level of harmonics generated by IVT and its ability to transform harmonics from high voltage (HV) to low voltage (LV) side. Complex voltages consisting of fundamental voltage and certain amount of superimposed harmonic are used to check the frequency response of IVT. RCFs and phase angle errors of the IVT are determined and can be applied to power quality monitors for compensation of errors that occur at high harmonic frequencies. Different test circuits are proposed for generation of HV consisting of fundamental voltage and harmonic voltages with amplitudes in range 5-15 % of the applied fundamental voltage. In order to improve the testing capabilities at higher voltage levels (for equipment with 123 kV≤Um≤420 kV), a compensation for both fundamental and harmonic voltages is proposed with a special connection through blocking and pass filters.

Inductive voltage transformer ; frequency response ; harmonic distortion ; power quality ; high voltage testing

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1-9.

2017.

objavljeno

Podaci o matičnoj publikaciji

4th International Colloquium "Transformer Research and Asset Management", Pula, Croatia, May 10 – 12, 2017

Zagreb: CIGRÉ

Podaci o skupu

4th International Colloquium "Transformer Research and Asset Management"

predavanje

10.05.2017-12.05.2017

Pula, Hrvatska

Povezanost rada

Elektrotehnika