Limitations of the bifurcation diagrams in the boost converter steady-state responses identification (CROSBI ID 245368)

Prilog u časopisu | prethodno priopćenje | međunarodna recenzija

Stojanović, Željko ; Pelin, Denis Limitations of the bifurcation diagrams in the boost converter steady-state responses identification // International journal of electrical and computer engineering systems, 88 (2017), 2; 59-65

Podaci o odgovornosti

Stojanović, Željko ; Pelin, Denis

engleski

Limitations of the bifurcation diagrams in the boost converter steady-state responses identification

Steady-state responses of the boost converter operating in discontinuous conduction mode of operation are identified by using bifurcation diagrams as characteristic simulation tool for identification of steady-state responses. The structure of simulated bifurcation diagrams is dependent on the starting period of sampling and initial instant of sampling. The influence of these parameters on calculation of bifurcation diagrams was studied. Some of possible issues, pitfalls and misinterpretations are commented as well as some recommendations about steady-state response identification are given.

bifurcation diagram ; identification ; steady-state responses ; boost converter ; sampling