Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

An Improved Method for Performance Testing of Partial Discharge Calibrators (CROSBI ID 671594)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Filipović-Grčić, Dalibor ; Filipović-Grčić, Božidar ; Novko, Ivan An Improved Method for Performance Testing of Partial Discharge Calibrators // 21st International Symposium on High Voltage Engineering. 2019. str. 1-12

Podaci o odgovornosti

Filipović-Grčić, Dalibor ; Filipović-Grčić, Božidar ; Novko, Ivan

engleski

An Improved Method for Performance Testing of Partial Discharge Calibrators

Partial discharges occur because of insulation defects, when the electric field amplitude locally exceeds the dielectric strength of the cavities inside the insulating material. The thermal, chemical and electrical phenomena associated with the partial discharges are dangerous for insulation systems of high voltage equipment, as they can accelerate the aging process. Therefore, partial discharge tests are nowadays prescribed as routine tests for most of the high voltage devices. The calibration of a partial discharge measuring system is carried out to determine its scale factor before every test. The calibration is performed with partial discharge calibrator. IEC 60270 describes methods used for the evaluation of the actual charge generated by the calibrator. However, some factors that may influence the performance test results regarding the influence of circuit components, partial discharge measuring system’s linearity, bandwidth and pulse train response on calibration are not specified. This paper presents an improved method for performance testing of partial discharge calibrators. A reference partial discharge calibrator was used, and the traceability of calibration was established. Various effects on calibration procedure were investigated such as the influence of circuit components, partial discharge measuring system’s linearity, bandwidth and pulse train response on calibration. Performed tests in this paper showed that these factors cannot be neglected and therefore an improved method for performance testing of partial discharge calibrators is proposed which considers mentioned factors and minimizes their influence on the calibration procedure.

partial discharges ; calibrator ; calibration methods ; charge measurement

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1-12.

2019.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

21st International Symposium on High Voltage Engineering

Podaci o skupu

21st International Symposium on High Voltage Engineering

predavanje

26.07.2019-30.07.2019

Budimpešta, Mađarska

Povezanost rada

Drvna tehnologija