Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Pseudoexfoliation syndrome and asymptomatic myocardial dysfunction (CROSBI ID 143440)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Bojić, Lovro ; Ermacora, Ratko ; Polić, Stojan ; Ivanisević, Milan ; Mandić, Zlatko, Rogosić, Velimir ; Lesin, Milan Pseudoexfoliation syndrome and asymptomatic myocardial dysfunction // Graefe's archive for clinical and experimental ophthalmology, 243 (2005), 5; 446-449

Podaci o odgovornosti

Bojić, Lovro ; Ermacora, Ratko ; Polić, Stojan ; Ivanisević, Milan ; Mandić, Zlatko, Rogosić, Velimir ; Lesin, Milan

engleski

Pseudoexfoliation syndrome and asymptomatic myocardial dysfunction

BACKGROUND: The purpose of this study was to investigate the frequency of asymptomatic left ventricular dysfunction in patients with pseudoexfoliation syndrome. METHODS: Two-dimensional and pulsed Doppler echocardiography of transmitral flow was performed on 27 patients with pseudoexfoliation syndrome, aged 66.9+/-5.6 years, and 24 healthy volunteers aged 63.9+/-6.5 years. Left ventricular (LV) systolic contraction and ejection were assessed by LV ejection fraction (EF) and fractional shortening (FS). LV diastolic filling parameters tested were: early fast diastolic filling (E wave), late diastolic filling (A wave), ratio E/A, velocity time integral E wave (VTIE) and A wave (VTIA), their ratio (VTIE/VTIA), pressure at the end of filling (LVEDP) and a pulmonary capillary wedge pressure (PCWP). RESULTS: Systolic parameters EF and FS, diastolic filling parameters such as A, LVEDP and PCWP were not significantly different between patients with pseudoexfoliation syndrome and controls (P>0.05). A significant difference (P<0.05) was found with regard to the diastolic filling parameters: E (61.6+/-15.1 vs 83.7+/-21.4), ratio E/A (0.8+/-0.1 vs 1.1+/-0.2), VTIE (8.6+/-1.8 vs 9.8+/-1.9), VTIA (10.3+/-2.4 vs 7.8+/-1.6) and ratio VTIA/VTIE (1.2+/-0.2 vs 0.8+/-0.2). CONCLUSION: Our study suggests the possibility of an association between patients with pseudoexfoliation syndrome and a discrete asymptomatic myocardial diastolic dysfunction.

pseudoexfoliation syndrome; myocardial diastolic dysfunction

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

243 (5)

2005.

446-449

objavljeno

0721-832X

Povezanost rada

Kliničke medicinske znanosti

Indeksiranost