Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Influence of local inflammation of the peritoneal membrane on diuresis and residual renal function in patients treated with peritoneal dialysis. (CROSBI ID 212555)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Jeličić, Ivo, Ljutić, Dragan ; Šain, Milenka ; Kovačić, Vedran ; Radić, Josipa Influence of local inflammation of the peritoneal membrane on diuresis and residual renal function in patients treated with peritoneal dialysis. // JOURNAL OF ARTIFICIAL ORGANS, 15(1) (2011), 65-70

Podaci o odgovornosti

Jeličić, Ivo, Ljutić, Dragan ; Šain, Milenka ; Kovačić, Vedran ; Radić, Josipa

engleski

Influence of local inflammation of the peritoneal membrane on diuresis and residual renal function in patients treated with peritoneal dialysis.

The aim of this study was to investigate the connection between local inflammation of the peritoneal membrane and diuresis, as well as the residual renal function (RRF) in patients treated with continuous ambulatory peritoneal dialysis (CAPD). Twenty patients treated with CAPD participated in this cross-sectional study. To determine the influence of local inflammation of the peritoneal membrane, effluent interleukin-6 (IL-6) and soluble interleukin-6 receptor (sIL-6R) levels were measured. The level of IL-6, in the group as a whole, was significantly higher in effluent (7.87 pg/mL) than in serum (1.29 pg/mL). There was a significant correlation between effluent and serum IL-6 (r = 0.608 ; P = 0.002). There was also a significant relationship between effluent and serum IL-6 and duration of CAPD treatment, respectively (r = 0.577 ; P = 0.004 ; r = 0.528 ; P = 0.008). Further, there was a significant negative correlation between effluent IL-6 and daily diuresis (r = -0.533 ; P = 0.008), but there was no significant correlation between effluent IL-6 and RRF (r = -0.339, P = 0.072). On the other hand, the concentrations of effluent IL-6 were significantly higher in patients with RRF <2 mL/min than in those with RRF ≥2 mL/min (P = 0.039). In conclusion, local inflammation has a significant impact on the amount of diuresis and probably on RRF in patients on CAPD.

peritoneal dialysis; inflammation; peritoneal membrane

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

15(1)

2011.

65-70

objavljeno

1434-7229

Povezanost rada

Kliničke medicinske znanosti

Indeksiranost