Ultrasensitive determination of trans-beta- carotene in rat and beef livers by means of high- performance liquid chromatography coupled with thermal lens detection (CROSBI ID 89601)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Luterotti, Svjetlana ; Sikovec, Mateja ; Bićanić, Dane Ultrasensitive determination of trans-beta- carotene in rat and beef livers by means of high- performance liquid chromatography coupled with thermal lens detection // Talanta, 53 (2000), 1; 103-113. doi: 10.1016/S0039-9140(00)00388-X

Podaci o odgovornosti

Luterotti, Svjetlana ; Sikovec, Mateja ; Bićanić, Dane

engleski

Ultrasensitive determination of trans-beta- carotene in rat and beef livers by means of high- performance liquid chromatography coupled with thermal lens detection

Hyphenated high-performance liquid chromatography (HPLC)-thermal lens spectrometry (TLS) was demonstrated as a method capable of selectively profiling carotenoids in animal livers and suitable for ultrasensitive determination of trans-beta-carotene in the same tissues. The new approach, HPLC-TLS, a first choice method when studying the tissues containing minute quantities of trans-beta-carotene such as in the case of rat liver, also proved useful in the analysis of beef liver. Due to high sensitivity of the HPLC-TLS method, there is no need for enrichment of liver extracts ; in fact, multifold diluted extracts can be analysed directly which not only preserves carotenoids from structural transformations, but also minimises the risk for contamination of the stationary phase. Furthermore, both the calibration in a matrix-matched medium and standard addition method have thus become unnecessary. Reliable determinations of trans- beta-carotene in rat and beef livers (recoveries 98.0 and 99.8%) were obtained by calibration in the mobile phase within the linearity range 1-130 ng/ml. In addition, favourable detection limits (0.39 and 0.49 ng/ml), precision of determination (2.8-7.2%) and the selectivity evidenced in the presence of multifold molar excess of vitamins A and E, cholesterol and lecithin, confirm the suitability of the method. The HPLC-TLS approach can be successfully applied in studies concerned with the biotransformation of beta-carotene which are of both scientific and public health interest.

trans-beta-carotene; HPLC-thermal lens spectrometry; rat liver; beef liver

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

53 (1)

2000.

103-113

objavljeno

0039-9140

10.1016/S0039-9140(00)00388-X

Povezanost rada

Fizika, Kemija, Kliničke medicinske znanosti

Poveznice
Indeksiranost