Rapid Determination of Oxalate by an Amperometric Oxalate Oxidase-Based Electrode (CROSBI ID 89960)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Milardović, Stjepan ; Grabarić, Zorana ; Rumenjak, Vlatko ; Jukić, Marijana Rapid Determination of Oxalate by an Amperometric Oxalate Oxidase-Based Electrode // Electroanalysis, 12 (2000), 13; 1-8-x

Podaci o odgovornosti

Milardović, Stjepan ; Grabarić, Zorana ; Rumenjak, Vlatko ; Jukić, Marijana

engleski

Rapid Determination of Oxalate by an Amperometric Oxalate Oxidase-Based Electrode

An enzymatic biosensor for determination of oxalate in different real food samples (spinach, sesame seed, tea leaves, and strawberries) as well as in human urine is described and evaluated. Amperometric oxalate biosensor is made from graphite (spetroscpic purity) electrode modified with chromium (III) heksacyanoferrate (II) film (CrHCF). Oxalate oxidase was immobilized using bovine serum albumin and glutaraldehyde cross-linking procedure. This enzyme biocatalyses the oxidation of oxalate to hydrogen peroxide and carbon dioxide. CrHCF film enables one to measure a current resulting in the reduction in the reduction of hydrogen peroxide at low potential (0 V vs. Hg/Hg_2Cl_2/3M KCl electrode), proportional to oxalate concentration. The electrocatalytic properties of CrHCF electrode were well pronounced in 0.05 M succinic buffer, pH 3.8, containing 0.1 M KCl and 5.4 mM EDTA. For determination of oxalate in some food matrices (tea leaves and strawberries) dialysis membrane as an outer coat was necessary to prevent electrochemical interferents. The sensitivity of biosensor was 31microA/(mM cm^2) in synthetic oxalic acid solutions. The biosensor has shown good linearity (R^2=0.9984) in the oxalate concentration range between 2.5 and 400 microM and its half-lifetime was longer than one month. The performance of the metod was compared with the reference enzymatic spectrophotometric method and a very good correlation was obtained between these results.

Chromium (III) heksacyanoferrate (II) modified electrode; Food analysis; Graphite electrode; Hydrogen peroxide reduction; Oxalate determination; Oxalate oxidase; Urine analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

12 (13)

2000.

1-8-x

objavljeno

1040-0397