Electrochemical Determination of Dissolved Uranium in Krka River Estuary (CROSBI ID 90720)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Djogić, Renata ; Pižeta, Ivanka ; Branica, Marko
engleski
Electrochemical Determination of Dissolved Uranium in Krka River Estuary
The applicability of the previously developed method for electrochemical determination of dissolved uranium concentration has been tested on natural water samples taken from the Krka river estuary during various seasons and along depth profiles. The method is based on the following treatment of the sample: destroying the uranyl-carbonato complexes by adjusting the pH to 3, enabling the formation of adsorbable uranyl-hydroxo complexes by adjusting the pH to 6.5 - 7.0 and measurement by cathodic stripping voltammetry technique. As the signal of dissolved uranium reduction is sometimes masked by the signal of the matrix of the sample, a resolution enhancement including digestion and/or deconvolution has to be applied. The measured concentration of dissolved uranium varies in the range from 0.4 to 3.3 x 10-8 mol l-1, corresponding to data found in the literature. The depth profile of dissolved uranium concentration distributions shows conservative behaviour. The X-ray fluorescence spectroscopy (XRF) confirmed the applicability of the method, yet pointing out to its limitations caused by the matrix of the solution.
dissolved uranium; cathodic stripping voltammetry; Krka river estuary; seawater
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano