Very fast analysis of impurities in immunoglobulin concentrates using conjoint liquid chromatography on short monolithic disks (CROSBI ID 241750)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Branović, Karmen ; Lattner, Gunter ; Barut, Miloš ; Štrancar, Aleš ; Josić, Đuro ; Buchacher, Andrea Very fast analysis of impurities in immunoglobulin concentrates using conjoint liquid chromatography on short monolithic disks // Journal of immunological methods, 271 (2002), 1-2; 47-58. doi: 10.1016/S0022-1759(02)00339-3

Podaci o odgovornosti

Branović, Karmen ; Lattner, Gunter ; Barut, Miloš ; Štrancar, Aleš ; Josić, Đuro ; Buchacher, Andrea

engleski

Very fast analysis of impurities in immunoglobulin concentrates using conjoint liquid chromatography on short monolithic disks

Transferrin and albumin are often present in immunoglobulin G (IgG) concentrates and are considered as impurities. Therefore, it is important to determine their concentration in order to obtain a well-characterized biological product. Here, we describe their determination based on conjoint liquid chromatography (CLC). The established method combines two different chromatographic modes in one step: affinity and ion-exchange chromatography (IEC) combined in one column. Therefore, two CIM Protein G and one CIM quaternary amine (QA) monolithic disks were placed in series in one housing forming a CLC monolithic column. Binding conditions were optimized in a way that immunoglobulins were captured on the CIM Protein G disks, while transferrin and albumin were bound on the CIM QA disks. Subsequently, transferrin and albumin were eluted separately by a stepwise gradient with sodium chloride, whereas immunoglobulins were released from the Protein G ligands by applying low pH. A complete separation of all three proteins was achieved in less than 5 min. The method permits the quantification of albumin and transferrin in IgG concentrates and has been successfully validated.

Monolithic column CLCConjoint liquid chromatography Immunoglobulin Albumin Transferrin Quantification Validation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

271 (1-2)

2002.

47-58

objavljeno

0022-1759

10.1016/S0022-1759(02)00339-3