Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Radiation load of children by chest radiodiagnostic measurements (CROSBI ID 467689)

Prilog sa skupa u zborniku | izvorni znanstveni rad

Nikodemova, Denisa ; Ranogajec-Komor, Maria ; Vladar, Milan ; Horvathova, Martina Radiation load of children by chest radiodiagnostic measurements // Zbornik radova Četvrtog simpozija Hrvatskog društva za zaštitu od zračenja = Proceedings of the 4th Symposium of the Croatian Radiation Protection Association / Obelić, Bogomil ; Franić, Zdenko (ur.). Zagreb: Hrvatsko društvo za zaštitu od zračenja, 1998. str. 309-314-x

Podaci o odgovornosti

Nikodemova, Denisa ; Ranogajec-Komor, Maria ; Vladar, Milan ; Horvathova, Martina

engleski

Radiation load of children by chest radiodiagnostic measurements

Radiodiagnostic examinations of children present particular importance from the radiation hygiene point of view. The estimation of the radiation load of pediatric patient is not easy, because of the lack of information about organ weighting factors for various ages of patients, as well as due to the differences in applied X-ray examination parameters. In the district of Slovak Republic, in which also the working Nuclear Power Plant Jaslovské Bohunice is included, efforts were done to estimate the radiation load of children to 15 years by chest radiodiagnostic examinations. The data of entrance surface doses were collected using measurements with TLD for 100 patients divided in 5 age categories at six radiodiagnostic departments. The calculations of the total absorbed dose were performed using the measured ESD values(the measured entrance surface dose in mGy) integrated over the X-ray beam area, the conversion factors between the imparted energy and the dose-area product and the known irradiation parameters (kV, HVL, mass, etc.). The analysis of the obtained absorbed doses (Ea) as a function of age for chest PA radiodiagnostic examinations has shown, that the investigated Slovak radiodiagnostic centres use rather lower voltage techniques and the entrance surface doses are much higher than the proposed value of European Communities.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

309-314-x.

1998.

objavljeno

Podaci o matičnoj publikaciji

Obelić, Bogomil ; Franić, Zdenko

Zagreb: Hrvatsko društvo za zaštitu od zračenja

953-96133-2-9

Podaci o skupu

4. simpozij Hrvatskog društva za zaštitu od zračenja

predavanje

11.11.1998-13.11.1998

Zagreb, Hrvatska

Povezanost rada

Kemija