Površinske doze pacijenata pri različitim CT pretragama (CROSBI ID 463330)

Prilog sa skupa u zborniku | izvorni znanstveni rad

Vekić, Branko ; Kovačević, Sandra ; Ranogajec- Komor, Maria ; Duvnjak, Neda ; Marušić, P. ; Anić, P. ; Dolenčić, P. Površinske doze pacijenata pri različitim CT pretragama // Zbornik radova Trećeg simpozija Hrvatskog društva za zaštitu od zračenja / Kubelka, Dragan ; Kovač, Jadranka (ur.). Zagreb: Hrvatsko društvo za zaštitu od zračenja, 1996. str. 237-243-x

Podaci o odgovornosti

Vekić, Branko ; Kovačević, Sandra ; Ranogajec- Komor, Maria ; Duvnjak, Neda ; Marušić, P. ; Anić, P. ; Dolenčić, P.

hrvatski

Površinske doze pacijenata pri različitim CT pretragama

Computed tomography (CT) has become a major source of the population exposure to diagnostic X-rays, and acknowledge of the doses delivered by the CT equipment has become very important. COnsiderable efforts should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The conditions of exposure in CT are quite different from dose in conventional X-ray imaging. This has required the development of specific techniques for assessing patient dose from CT. The aims of this work were to determine the dose delivered to various organs of patients undergoing computed tomography of abdomen, thorax, pelvis and kideny as measured on the surface of the body and to estimate the risk to the patients. Dosimetric measurements were performed at two different CT scanners (Siemens SOMATOM DR-H ve.r HC-1 and Shimadzu SCT-4500TE). The doses absorbed by different organs (gonads, chest, thyroid and eye lens) and by the examined part of the body of 95 patients of various sex and age were measured with TLD-700. The doses absorbed by different organs during the diagnostic CT examination of the body depend on the technical parameters, such as the number of scans, mAs, the thickness of scans, scanning times, tube voltage and other characteristics, some of each depend on the type and severity of illness. Clinical parameters, such as patient size and composition, and patient cooperation with regard to the control and motion, also influence the dose and the image quality. The highest dose measured in this study (89.19 mGy) was delivered to kidney during CT examination of this organ.

površinske doze; pacijent; CT pretrage

nije evidentirano

engleski

Patient surface doses in computerized tomography examinations

nije evidentirano

surface doses; patient; computerized tomography examinations

nije evidentirano

Podaci o prilogu

237-243-x.

1996.

objavljeno

Podaci o matičnoj publikaciji

Kubelka, Dragan ; Kovač, Jadranka

Zagreb: Hrvatsko društvo za zaštitu od zračenja

Podaci o skupu

Treći simpozij Hrvatskog društva za zaštitu od zračenja

predavanje

20.11.1996-22.11.1996

Zagreb, Hrvatska

Povezanost rada

Kemija