Sekundarni standardni dozimetrijski laboratorij Instituta "Ruđer Bošković", Zagreb (CROSBI ID 511245)

Prilog sa skupa u zborniku | stručni rad

Vekić, Branko ; Ban, Renata ; Miljanić, Saveta Sekundarni standardni dozimetrijski laboratorij Instituta "Ruđer Bošković", Zagreb // Zbornik radova 6. simpozija Hrvatskog društva za zaštitu od zračenja / Garaj-Vrhovac, Verica ; Kopjar, Nevenka ; Miljanić, Saveta (ur.). Zagreb: Hrvatsko genetičko društvo, 2005. str. 40-48-x

Podaci o odgovornosti

Vekić, Branko ; Ban, Renata ; Miljanić, Saveta

hrvatski

Sekundarni standardni dozimetrijski laboratorij Instituta "Ruđer Bošković", Zagreb

The Secondary Standard Dosimetry Laboratory at the Ruđer Bošković Institute, Zagreb, Croatia, was installed during the several last years. The installation of this Laboratory was strongly supported by the International Atomic Energy Agency (IAEA) through the Technical Cooperation Project (CRO 1/004/ ; Establishing Calibration Services). Inside the country this Technical Cooperation Project was supported by the State Office for Standardization and Metrology, State Office for Radiation Protection and the Ministry of Health of the Republic of Croatia. The Secondary Standard Dosimetry Laboratory at the Ruđer Bošković Institute, Zagreb, Croatia was installed in two calibration rooms. The both of these calibration rooms are 9.6 meters long and 6 meters wide. In the both of these calibration rooms the proper climatisation was installed. The walls of the both calibration rooms are thick enough (1 meter of concrete) and the entrance doors are protected by Pb to prevent of any radiation hazard in control rooms, in neighbouring rooms and in environment. In the first calibration room placed in the basement two sealed sources share the same calibration bench (produced by Hopewell Designs, Inc., USA) between them which is 6 meters long. On one side is 60Co source of the 30 TBq activity (December 2004) for the calibration of radiotherapy ionising chambers and the other equipment in the field of high dose rate range. On the other side is irradiation unit consists of 2 sealed sources for radiation protection purposes: (1) 137Cs source, activity of 740 MBq (February 2004) and (2) 60Cosource, activity of 185 MBq (February 2004). For this second source three attenuators are provided that give a nominal attenuation of x10, x100 and x1000. In the second calibration room placed just above the first one the X-ray unit (gift from PTB, Germany, ISOVOLT 420, 40-300 kV, 1-20 mA) is placed. In front of X-ray tube there are: (1) Aperture Wheel Assembly designed to modify the beam diameter of the X-ray to meet the various beam configurations required for calibration instruments, (2) a set of Filter Assembly to produce the beam definition as called for in the ISO 4037-3, (3) the Half-Value Layer Kit, and (4) the calibration bench (produced by Hopewell Designs, Inc., USA) 5 meters long. All ionisation chambers and electrometers used in SSDL are calibrated in Primary Standard Dosimetry Laboratory (PTB, Germany) or in Secondary Standard Dosimetry Laboratory of the International Atomic Energy Agency.

SSDL; dozimetrija; ionizacijske komore; izvori gama zračenja; X zračenja

nije evidentirano

engleski

Secondary standard dosimetry laboratory at the Ruđer Bošković Institute, Zagreb

nije evidentirano

SSDL; dosimetry; ionization chambers; gamma ray sources; X rays

nije evidentirano

Podaci o prilogu

40-48-x.

2005.

objavljeno

Podaci o matičnoj publikaciji

Garaj-Vrhovac, Verica ; Kopjar, Nevenka ; Miljanić, Saveta

Zagreb: Hrvatsko genetičko društvo

Podaci o skupu

6. Simpozij Hrvatskog društva za zaštitu od zračenja

predavanje

18.04.2005-20.04.2005

Stubičke Toplice, Hrvatska

Povezanost rada

Kemija