Simulation of the ALICE DAQ and Trigger system (CROSBI ID 756828)
Druge vrste radova | ostalo
Podaci o odgovornosti
Antičić, Tome
engleski
Simulation of the ALICE DAQ and Trigger system
The ALICE Trigger and Data Acquisition (TRG/DAQ) System is required to support an aggregate event building bandwidth of up to 4 GByte/s and a storage capability of up to 1.25 GByte/s to mass storage.The system has been decomposed in a set of hardware and software components and prototypes of these components are being developed. It is necessary to verify the system design, its capability to reach the expected behavior and the target performances, discover possible bottlenecks and ways to correct for them, and explore alternative algorithms and new architectures. To achieve this the complete TRG/DAQ system has been formally specified, and the verification of the expected behavior has been performed through the execution of the specification.
DAQ; trigger; simulation; ALICE
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
ALICE Internal Note 2003-001
2003.
nije evidentirano
objavljeno