Critical evaluation of the use of total reflection X-ray fluorescence spectrometry for the analysis of whole blood samples: application to patients with thyroid gland diseases (CROSBI ID 269963)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Margui, Eva ; Jablan, Jasna ; Gerić, Marko ; Inić, Suzana ; Domijan, Ana-Marija ; Janušić, Renatio ; Šarčević, Božena ; Queralt, Ignasi ; Garaj-Vrhovec, Verica Critical evaluation of the use of total reflection X-ray fluorescence spectrometry for the analysis of whole blood samples: application to patients with thyroid gland diseases // Analytical & bioanalytical chemistry, 411 (2019), 1659-1670. doi: doi.org/10.1007/s00216-019-01618-3

Podaci o odgovornosti

Margui, Eva ; Jablan, Jasna ; Gerić, Marko ; Inić, Suzana ; Domijan, Ana-Marija ; Janušić, Renatio ; Šarčević, Božena ; Queralt, Ignasi ; Garaj-Vrhovec, Verica

engleski

Critical evaluation of the use of total reflection X-ray fluorescence spectrometry for the analysis of whole blood samples: application to patients with thyroid gland diseases

Multielemental analysis of whole blood can provide significant information for the evaluation of nutritional status and diagnosis of certain diseases as well as for the assessment of exposure to potentially toxic metals. However, the quantification of multiple elements in whole blood is not easy partly because of the wide variation in element concentrations (from ng L−1 to g L−1) and the complex matrix. The aim of this work was to develop a fast, sustainable, and reliable analytical method, in combination with low- power TXRF, for multielemental analysis of blood samples. Firstly, a set of experiments were carried out to select the best diluent type and dilution factor using the control material SeronormTM Trace Elements Whole Blood L-1. A critical evaluation of the parameters affecting the sample deposition on the reflector was also carried out including a study of the shape and element distribution of the deposited residue on the reflector by micro X-ray fluorescence spectrometry. Using the best analytical conditions, limits of detection estimated were in the low milligrams per kilogram range and similar to those obtained using more complex sample treatments such as digestion. Accuracy and precision of the results were in most cases acceptable (recoveries 89– 102%, RSD 6–8%, n = 5). Only underestimated values were obtained for light elements such as potassium. To prove the applicability of the method, several blood samples from control and thyroid disease patients were analyzed. Despite the fact that more samples need to be analyzed, it seems that Zn and Br contents in some of the patients are significantly higher compared to control samples.

Whole blood, Multielement analysis, TXRF, Thyroid

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

411

2019.

1659-1670

objavljeno

1618-2642

1618-2650

doi.org/10.1007/s00216-019-01618-3