On determination JIc parameter using a CN plate specimen (CROSBI ID 159007)

Prilog u časopisu | izvorni znanstveni rad

Božić, Željko On determination JIc parameter using a CN plate specimen // Transactions of FAMENA, 24 (2000), 47-54

Podaci o odgovornosti

Božić, Željko

engleski

On determination JIc parameter using a CN plate specimen

A procedure for determination of the critical J-integral parameter value, JIc, associated with the onset of stable crack propagation under Mode I deformation is presented in this paper. Fracture tests were carried out for centrally notched tension plate specimen - CN. The experiments have shown that the large scale yielding occurred in the specimen ligaments and some stable fracture proceeded to the plastic collapse. The elastic-plastic fracture mechanics concept was employed in fracture analysis. Finite element simulations, including both large deformation and elastic-plastic material behaviour were performed. J-integral and crack tip opening displacement, δt, values, were calculated using post-processing procedures. Combining numerical results of the δt values, with the corresponding experimentally obtained value associated with the crack propagation onset, the JIc value was estimated.

CN plate specimen; Elastic-plastic fracture; J-integral

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

24

2000.

47-54

objavljeno

1333-1124

Povezanost rada

Strojarstvo, Zrakoplovstvo, raketna i svemirska tehnika