Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Specific Characteristics of Ocular Biometric Factors in Glaucomatous Patients with Pseudoexfoliative Syndrome as Measured by Optical Low-Coherence Reflectometry. (CROSBI ID 265957)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Janjetović, Željka ; Bušić, Mladen ; Bosnar, Damir ; Barać, Josip ; Genda, Ivanka Specific Characteristics of Ocular Biometric Factors in Glaucomatous Patients with Pseudoexfoliative Syndrome as Measured by Optical Low-Coherence Reflectometry. // Acta clinica Croatica, 58 (2019), 1; 87-94. doi: 10.20471/acc.2019.58.01.11

Podaci o odgovornosti

Janjetović, Željka ; Bušić, Mladen ; Bosnar, Damir ; Barać, Josip ; Genda, Ivanka

engleski

Specific Characteristics of Ocular Biometric Factors in Glaucomatous Patients with Pseudoexfoliative Syndrome as Measured by Optical Low-Coherence Reflectometry.

The aim of the study was to assess biometric factor aberrations and differences among groups of eyes with cataract and pseudoexfoliative syndrome, cataract and pseudoexfoliative glaucoma, and cataract and primary open-angle glaucoma (POAG), and to determine biometric factors of the eye specific for the group of glaucomatous patients with pseudoexfoliative syndrome by use of optical low-coherence reflectometry. This retrospective study included 72 patients, and the study sample of 102 eyes was divided into the following three groups according to diagnosis: 29 eyes with pseudoexfoliative syndrome and cataract ; 36 eyes with POAG and cataract ; and 37 eyes with pseudoexfoliative glaucoma and cataract. Data on biometric measurements (central corneal thickness, pupillary diameter, anterior chamber depth, lens thickness, axial length, retinal thickness, astigmatism and white-to-white) obtained by use of optical low-coherence reflectometry on a Lenstar LS 900® (Haag-Streit International) were collected and analyzed by thorough survey of medical documentation of patients scheduled for cataract surgery at Department of Ophthalmology, Sveti Duh University Hospital in Zagreb, Croatia. Comparative analysis of the groups yielded statistically significant differences in central corneal thickness (F2/99=7.066 ; p=0.001) and lens thickness (F2/96=5.133 ; p=0.008). The group of eyes diagnosed with pseudoexfoliative glaucoma and cataract had a significantly thinner cornea as compared with the other two groups and a significantly thicker lens as compared with the group of eyes with POAG and cataract. In conclusion, optical low-coherence reflectometry revealed differences in biometric factors among the three groups of eyes, with a statistically significantly thinner cornea and thicker lens in the group of glaucomatous patients with pseudoexfoliative syndrome.

Exfoliation syndrome ; Optic low-coherence reflectometry ; Glaucoma, open-angle ; Cataract

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

58 (1)

2019.

87-94

objavljeno

0353-9466

1333-9451

10.20471/acc.2019.58.01.11

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost