Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Spatial Distortion Assessments of a Low-Cost Laboratory and Field Hyperspectral Imaging System (CROSBI ID 269728)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Krtalić, Andrija ; Miljković, Vanja ; Gajski, Dubravko ; Racetin, Ivan Spatial Distortion Assessments of a Low-Cost Laboratory and Field Hyperspectral Imaging System // Sensors, 19 (2019), 19; 4267, 19. doi: 10.3390/s19194267

Podaci o odgovornosti

Krtalić, Andrija ; Miljković, Vanja ; Gajski, Dubravko ; Racetin, Ivan

engleski

Spatial Distortion Assessments of a Low-Cost Laboratory and Field Hyperspectral Imaging System

This article describes the adaptation of an existing aerial hyperspectral imaging system in a low-cost setup for collecting hyperspectral data in laboratory and field environment and spatial distortion assessments. The imaging spectrometer system consists of an ImSpector V9 hyperspectral pushbroom scanner, PixelFly high performance digital CCD camera, and a subsystem for navigation, position determination and orientation of the system in space, a sensor bracket and control system. The main objective of the paper is to present the system, with all its limitations, and a spatial calibration method. The results of spatial calibration and calculation of modulation transfer function (MTF) are reported along with examples of images collected and potential uses in agronomy. The distortion value rises drastically at the edges of the image in the near-infrared segment, while the results of MTF calculation showed that the image sharpness was equal for the bands from the visible part of the spectrum, and approached Nyquist’s theory of digitalization. In the near-infrared part of the spectrum, the MTF values showed a less sharp decrease in comparison with the visible part. Preliminary image acquisition indicates that this hyperspectral system has potential in agronomic applications.

imaging spectrometer ; pushbroom scanner ; spatial calibration ; MTF

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

19 (19)

2019.

4267

19

objavljeno

1424-8220

10.3390/s19194267

Trošak objave rada u otvorenom pristupu

APC

Povezanost rada

Geodezija, Interdisciplinarne prirodne znanosti

Poveznice
Indeksiranost