Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Electromyographic evaluation of the influence of denture adhesive on retention and stability of complete dentures (CROSBI ID 487790)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa

Alajbeg Ž., Iva ; Valentić-Peruzović, Melita ; Illeš, Davor ; Knezović-Zlatarić, Dubravka ; Alajbeg, Ivan Electromyographic evaluation of the influence of denture adhesive on retention and stability of complete dentures // Book of abstracts of 26th Annual Conference of EPA. Zagreb, 2002. str. 110-110-x

Podaci o odgovornosti

Alajbeg Ž., Iva ; Valentić-Peruzović, Melita ; Illeš, Davor ; Knezović-Zlatarić, Dubravka ; Alajbeg, Ivan

engleski

Electromyographic evaluation of the influence of denture adhesive on retention and stability of complete dentures

Improving retention and stability of complete dentures is of considerable interest in prosthetic dentistry. Approaches to this problem over the years have included overdentures, implants and denture adhesives. Although the denture adhesives are widely used, there are few quantitative data on the effects of an adhesive on denture retention and stability during normal functional activities. The purpose of this investigation was to study the influence of denture adhesive on the surface EMG activity of the masticatory muscles in the sample of complete denture wearers. In this study 6 denture wearers were investigated. Surface EMG recordings were obtained from left and right anterior temporal and masseter muscle and from the sub-mandibular group in the region of the anterior belly of the digastric muscle on the left and right side. Data were recorded during standardized jaw positions that included clenching in the position of maximal intercuspation of teeth (at 100%, 50% and 25% of the maximum activity), lateral eccentric positions, maximal lateral eccentric positions, protrusion, maximal protrusion and wide opening. The results have demonstrated higher digastric muscle activity in protrusion with the teeth at an edge-to-edge position after the use of adhesive (p<0, 05). In laterotrusive position, after the use of adhesive, the working side elevator muscles activities increased, although without any statistical significance (p>0, 05). This investigation points out that patients were able to produce greater levels of muscle activity in protrusive and laterotrusive position with the use of the adhesive.

etention; stability; complete dentures; denture adhesive

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

110-110-x.

2002.

objavljeno

Podaci o matičnoj publikaciji

Book of abstracts of 26th Annual Conference of EPA

Zagreb:

Podaci o skupu

26th Annual Conference of Europeean Prosthodontioc Association

poster

01.01.2002-01.01.2002

Cavtat, Hrvatska

Povezanost rada

Dentalna medicina