Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

An accurate absolute-scale measurement of bremsstrahlung following absorption of incident X- and gamma-rays (CROSBI ID 98417)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Pašić, Selim ; Ilakovac, Ksenofont An accurate absolute-scale measurement of bremsstrahlung following absorption of incident X- and gamma-rays // Radiation physics and chemistry (1993), 61 (2001), 3-6; 395-396-x

Podaci o odgovornosti

Pašić, Selim ; Ilakovac, Ksenofont

engleski

An accurate absolute-scale measurement of bremsstrahlung following absorption of incident X- and gamma-rays

Measurement has been made of the spectrum of bremsstrahlung due to photoelectrons ejected by incident photons of enegry 59.537 keV. Use was made of a coincidence setup with two HP germanium detectors, the target-detector recording the energy of the ejected photoelectron after it radiated bremsstrahlung photon and a second detector measuring the energy of the radiated bremsstrahlung photon. Detailed analysis of the applied experimental method was undertaken. Also included in this report are details of the processing of the data, including calculations of various detector-to-detector cross-talk processes. Experimental values of cross-sections are in good agreement with calculated values obtained using either the well-known semi-experimental thick-target formula or a simple theoretical model of bremsstrahlung radiation due to photoelectrons in an infinitely thick target.

Bremsstrahlung radiation; coincidence measurement; cross-section; photoelectric effect

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

61 (3-6)

2001.

395-396-x

objavljeno

0969-806X

Povezanost rada

Fizika

Indeksiranost