Solutions for Mechanical and Electromagnetic Problems in Bulb Type Hydropower Unit (CROSBI ID 488724)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Maljković, Zlatko ; Tešnjak, Sejid ; Pavlica, Milutin ; Jarić, Vladimir ; Bacinger, Ivan ; Magić, Damir ; Dvekar Đuro
engleski
Solutions for Mechanical and Electromagnetic Problems in Bulb Type Hydropower Unit
The paper presents the results of studying the specific problems that occurred during the exploitation of two bulb generators, and the methods for solving them. The paper focuses particularly on two groups of problems, which were more pronounced on only one of the two hydropower units, and these are increased vibrations of the hydropower unit and electromechanical oscillations, which significantly depend on the operating point of the drive. Non-standard solutions are mentioned which tend to eliminate the problem of vibrations by short-circuiting the excitation winding of one pole, in order to compensate for geometric non-symmetry by magnetic non-symmetry. The resulting problems have stimulated the user to install several sensors into the generator itself, thus enabling the measuring of the otherwise, in other generators non-measurable values (air gap width, flux density in air-gap, etc.) and thus allowing easier and more accurate interpretation of phenomena, as well as repair of the resulting problems during the operation of the hydropower unit
Bulb generator; Vibration; Power oscillation
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
11-303-x.
2002.
objavljeno
Podaci o matičnoj publikaciji
CIGRE 2002 SESSION PAPERS, Group 11 - Roating Machines
CIGRE
Pariz: CIGRÉ
Podaci o skupu
39th CIGRE Session
predavanje
25.08.2002-30.08.2002
Pariz, Francuska