Identification of hydrogen trapping in oil well steel by scanning electron microscopy
Based on the field report, wsudden cr4aking of C-Mn-V tubing occured of one 3000 m deep oil well. The damaged tuing was removed and analyzed by usual methods: chemical analysis. mechanical tasting, metallography, scanningelectron microskopy and X-ray diffraction. Tensocorrosion experiments were performed too in order to asses the sensitivity of steel to sulfide stress corrosion cracking. For this purpose, the samples were machined out of the pipe material and examined in laboratory according to the standardized procedure.
electron microscopy
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
404-405-x.
2003.
objavljeno
Podaci o matičnoj publikaciji
Milat, Ognjen ; Ježek, Davor
Zagreb: Croatian Society for Electron Microskopy
Podaci o skupu
6. Multinational Congress on Microskopy - European Extension
poster
01.06.2003-05.06.2003
Pula, Hrvatska