Second-generation Hybrid capture test and Amplicor monitor test generate highly correlated hepatitis B virus DNA levels (CROSBI ID 101291)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Poljak, M. ; Marin, I.J. ; Seme, K. ; Brinovec, V. ; Maticic, M. ; Meglic-Volkar, J. ; Lesnicar, G. ; Vince, A.
engleski
Second-generation Hybrid capture test and Amplicor monitor test generate highly correlated hepatitis B virus DNA levels
The performance of the Digene Hybrid Capture II HBV DNA Test HC II and the Roche Cobas Amplicor Monitor Test (Cobas-HBV) was evaluated on 252 serum samples. One hundred and seventy-three samples were HBV DNA positive and 75 HBV DNA negative by both assays. Four samples were HBV DNA positive by Cobas-HBV only. Linear regression analysis showed that the HBV DNA concentrations obtained from both assays were significantly related (n=173, r=0.976, P<0.0001). The results of the study show that Hybrid capture II and Cobas-HBV could be used equally in the management for patients with chronic HBV infection.