Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

The Rietveld refinement of XRD data obtained on nanocrystalline TiO2 (CROSBI ID 491472)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa

Djerdj, Igor ; Tonejc, Anđelka ; Tonejc, Antun The Rietveld refinement of XRD data obtained on nanocrystalline TiO2 // Twelfth Croatian-Slovenian Crystallographic meeting, Book of abstracts / Cetina, Mario ; Kajfež, Tanja ; Popović, Stanko et al. (ur.). Zagreb: Hrvatska akademija znanosti i umjetnosti (HAZU) ; Hrvatska Kristalografska Zajednica, 2003. str. 35-x

Podaci o odgovornosti

Djerdj, Igor ; Tonejc, Anđelka ; Tonejc, Antun

engleski

The Rietveld refinement of XRD data obtained on nanocrystalline TiO2

TiO2 is used in many applications such as photovoltaic devices, integrated wave guides, gas and humidity sensors, inorganic membranes, catalyst supports and electrochemical displays. Due to the grain-size dependence of structural parameters of nanocrystalline TiO2 such as: lattice parameters, Debye-Waller factors, microstrain, etc..., it seems obvious to explore this dependence and find smooth function which matches to experimental data. In this work we examined different (undoped and iron-doped) TiO2 samples prepared by the sol-gel route. They were characterised by means of X-ray diffraction measurements (XRD) on a Philips powder diffractometer (PW 1820) and selected area electron diffraction (SAED) by using JEOL JEM 2010 200 kV microscope, Cs=0.5 mm, point resolution of 0.19 nm. The Rietveld refinement of XRD and SAED data was applied in order to extract structural parameters such as unit cell parameters, bond lengths and angles. The obtained XRD patterns were analyzed by the Rietveld method using program FULLPROF [J. Rodriguez-Carvajal, FULLPROF- A program for Rietveld Refinement, Laboratoire Leon Brillouin, CEA-Saclay, France]. The values of refined unit cell parameters a and c of anatase are above/below ICDD values (a0=0.37852 nm, c0=0.95139 nm) within our grain size range (5-12 nm). By the increase of average grain size, the anatase unit cell parameters are approaching to ICDD values obtained from conventional polycrystalline materials. Fitting the relative deviations from ICDD values  a,  c ( a=(a-a0)/a0) to the inverse average grain size 1/D, asumming potential scaling law  a,  c 1/D , we obtained almost linear dependence for parameter c ( =0.9 0.2) and almost squared dependence for parameter a ( =2.0 0.6). Similarly, the fitting of r.m.s. microstrain   2 0.5 to the inverse average grain size yielded to exponent value  =0.7 0.2. The relative deviations from ICDD values  a,  c and r.m.s. microstrain   2 0.5 could be identified as a measure of defects, or more precisely defect concentration cd in nanocrystalline material. A model in which defects are uniformly distributed throughout individual grains, but present in larger concentration with smaller grain-sizes, such that cd 1/D, could be the model which gave the best description of observed grain-sized behaviour of TiO2 prepared by the sol-gel method [Eastman  Fitzsimmons, J. Appl. Phys. 77 (2), (1995) 522-527]. Significant changes of lattice parameters were found between undoped and iron doped samples in parameter a for 0.08 % and c 0.69 % (XRD) and a 1.6 %, c 0.5 % (SAED). The changes are observed in bond lengths and angles.

Rietveld; nanocrystalline

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

35-x.

2003.

objavljeno

Podaci o matičnoj publikaciji

Twelfth Croatian-Slovenian Crystallographic meeting, Book of abstracts

Cetina, Mario ; Kajfež, Tanja ; Popović, Stanko ; Štefanić, Zoran

Zagreb: Hrvatska akademija znanosti i umjetnosti (HAZU) ; Hrvatska Kristalografska Zajednica

Podaci o skupu

Twelfth croatian-slovenian crystallographic meeting

predavanje

19.06.2003-23.06.2003

NP Plitvička jezera, Hrvatska

Povezanost rada

Fizika