Plasma levels of vasoactive peptides (proANP and BigET-1) and solubile adhesion molecules (sICAM- 1) in patients with acute myocardial infarction (AMI) treated by percutaneous coronary intervention (PCI) (CROSBI ID 493377)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Vrkić, Nada ; Nikolić-Heitzler, Vjeran ; Žarković, Neven ; Begonja, Antonija ; Topić, Elizabeta Plasma levels of vasoactive peptides (proANP and BigET-1) and solubile adhesion molecules (sICAM- 1) in patients with acute myocardial infarction (AMI) treated by percutaneous coronary intervention (PCI) // Clinical chemistry and laboratory medicine. Special supplement / Siest, Gerard (ur.). 2002. str. S310-S310

Podaci o odgovornosti

Vrkić, Nada ; Nikolić-Heitzler, Vjeran ; Žarković, Neven ; Begonja, Antonija ; Topić, Elizabeta

engleski

Plasma levels of vasoactive peptides (proANP and BigET-1) and solubile adhesion molecules (sICAM- 1) in patients with acute myocardial infarction (AMI) treated by percutaneous coronary intervention (PCI)

The aim of the study was to assess plasma levels sICAM-1, BigET-1 and proANP in samples from periferal venous and coronary artery blood in patients with AMI treated by percutaneous coronary intervention (PCI). Twentysix patients (median 58, 5 yrs) admitted to the Coronary Care Unit were studied. Treatment by PCI was started within two hours of pain onset and blood samples were taken from periferal venous (V) and occluded coronary artery (A). Wilcoxon and Pearson tests were used for statistical evaluation. The medians of BigET-1 (fmol/ml) and proANP (fmol/ml) were elevated according to reference values: A=3, 30 ; V=2, 85 and A=2133, 8 ; V=3031, 3 respectively. The medians of sICAM-1 (ng/ml) were in reference interval: A=254, 0 ; V=248, 5. Only proANP values of A samples were statistically different (lower levels) from V samples (P=0, 035). Positive correlation was found for the pairs A-V of all analytes: BigET (r=0, 601 ; P=0, 00116), sICAM (r=0, 641 ; P=0, 004) and proANP (r=0, 799 ; P=0, 00001). The correlation between pairs of A samples for proANP and sICAM was significant (r=0, 505 ; P=0, 00859). Specific local cardiac events showed diminished ANP and sICAM secretion in comparison with periferal levels, probably by higly activated vasoconstriction system induced by strong reduced blood flow distal of occlusion.

sICAM-1; BigET-1; proANP; plasma; acute myocardial infarction; percutaneous coronary intervention

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

S310-S310.

2002.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Clinical chemistry and laboratory medicine. Special supplement

Siest, Gerard

Berlin: W. de Gruyter

1437-8523

Podaci o skupu

International congress of clinical chemistry and laboratory medicine (18 ; 2002)

poster

20.10.2002-25.10.2002

Kyoto, Japan

Povezanost rada

Temeljne medicinske znanosti, Farmacija

Poveznice