Analysis of cooling and heating of water with flat-plate solar radiators (CROSBI ID 494336)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Balen, Igor ; Soldo, Vladimir ; Kennedy, David Analysis of cooling and heating of water with flat-plate solar radiators // CD Proceedings of 2nd Dubrovnik Conference on Sustainable Development of Energy, Water and Environment Systems / Guzović, Zvonimir (ur.). Zagreb: Fakultet strojarstva i brodogradnje Sveučilišta u Zagrebu, 2003

Podaci o odgovornosti

Balen, Igor ; Soldo, Vladimir ; Kennedy, David

engleski

Analysis of cooling and heating of water with flat-plate solar radiators

Extensive analysis of flat-plate radiative panels operating using average hourly weather data for a maritime climate region was conducted. The panels are integrated in the space-ventilation system with air-cooling by means of a cold-water coil. Their primary function is to prepare a sufficient quantity of cold water, integrating radiative and convective cooling, that is collected in a cold-water tank during the nighttime operation. The cold water is used for cooling of the air during daytime. By small modification during daytime, solar panels could be turned into collectors and used to produce the hot water that is collected in a separate tank. A simulation model for the parametric analysis of the system in summer operating conditions and the influence of its components on the systems operation was developed. The model includes the control of the system's operation, which prevents water circulation in the periods without cooling/heating contributions. The purpose of the research was to predict the system behaviour in Irish climatic conditions, to enable sizing and design of the test rig that is to be built for experimental validation as part of a current large research project. The results were presented in the appropriate charts, where the influence of the main parameters on the system&#8217 ; ; s operation was illustrated. The results showed that the same system, with small modifications to the physical set-up, could provide a significant proportion of the hot water heating requirements in the daytime operation.

flat-plate radiative panels; space-ventilation; air-cooling

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

2003.

objavljeno

Podaci o matičnoj publikaciji

Guzović, Zvonimir

Zagreb: Fakultet strojarstva i brodogradnje Sveučilišta u Zagrebu

Podaci o skupu

Sustainable Development of Energy, Water and Environment Systems

predavanje

15.06.2003-20.06.2003

Dubrovnik, Hrvatska

Povezanost rada

Strojarstvo