Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

ITI implant-supported dentures: assesment of peri-implant bone changes (CROSBI ID 739486)

Prilog sa skupa u časopisu | izvorni znanstveni rad

Knezović Zlatarić, Dubravka ; Čelebić, Asja ; Pandurić, Josip ITI implant-supported dentures: assesment of peri-implant bone changes // Acta stomatologica Croatica. 2002. str. 339-x

Podaci o odgovornosti

Knezović Zlatarić, Dubravka ; Čelebić, Asja ; Pandurić, Josip

engleski

ITI implant-supported dentures: assesment of peri-implant bone changes

Mandibular overdenutres, supported by osseointegrated implants, is a well established, successful treatment of partialy edentulous patients. The aim of the study was to analyse the bone mineral density (BMD) in implant site of the mandibles with ITI implant-supported overdentures when compared with the same site of the edentulous mandibles in complete denture wearers. Eight patients (4 males, 4 females) with 16 ITI implants and overdentures in the mandible and 8 complete denture wearers (4 males, 4 females) who had approximately the same body mass index and the same age participated. The BMD measurements were performed on digitised periapical radiographs with a 10 steps copper stepwedge attached to each film. Grey levels of each step of the stepwedge were transformed to optical density values and using the 3rd degree polynomial the regression formula was calculated for each film. The BMD values of each measured region of interest (ROI) were expressed in the copper stepwedge thickness equivalents. BMD values of the ROIs close to the implant were statistically compared to the same ROIs in the edentulous mandible using t-test for independent samples. BMD values were significantly higher in ITI implant ROIs compared to the matching edentulous mandible sites (p<0.05). We concluded that an increased function after the implant-overdenture treatment caused a load-related bone formation which minimizes the physiologic age-related mandibular BMD loss.

ITI implant system

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

339-x.

2002.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

0001-7019

Podaci o skupu

Nepoznat skup

ostalo

29.02.1904-29.02.2096

Povezanost rada

Dentalna medicina