Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Evaluation of the mandibular bone quality in complete and removable partial denture wearers (CROSBI ID 495166)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Knezović Zlatarić, Dubravka ; Čelebić, Asja Evaluation of the mandibular bone quality in complete and removable partial denture wearers // The impact of prosthetic ptherapy on the quality of life / EPA (ur.). Ženeva: European Pressphoto Agency (EPA), 2003. str. 16/111-x

Podaci o odgovornosti

Knezović Zlatarić, Dubravka ; Čelebić, Asja

engleski

Evaluation of the mandibular bone quality in complete and removable partial denture wearers

The objective of this study was to determine whether the mandibular bone mineral density (BMD) and some linear radiomorphometric measurements on panoramic radiograph (PR) are correlated with different type of denture wearing (complete dentures or removable partial dentures - tooth supported Kennedy class I). In a total of 136 dental panoramic radiographs (DPR) the following parametars were evaluated: thickness of the mandibular cortex below the mental foramen, thickness of the mandibular cortex at the antegonion and gonion ; and panoramic mandibular index. Using the dental PRs and copper stepwedge, the mandibular BMD was investigated densitometrically. All the BMD values were expressed in equivalents of the actual stepwedge thickness. The results revealed statisticalaly significant difference in all the measured radiomorphomoetric indices between partial and complete denture wearers with AI, GI, MI and PMI higher in removable partial denture wearers. Statistically significant difference was also found in BMD values between partial and complete denture wearers, on the upper border of the mandibular residual alveolar ridge, under the denture base, with BMD values higher in removable partial denture wearers. The results support the idea that under the base of mucosa borne dentures occlusal forces stimulate bone resosrption, while under the base of tooth and mucosa borne dentures, occlusal forces may even cause apposition of the bone. Ovaj rad dobio je "Rowland Fereday Award" na 27-oj godišnjoj konferenciji Europskog protetskog udruženja

radiomorphometric indices; mandible; age; gender

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

16/111-x.

2003.

objavljeno

Podaci o matičnoj publikaciji

EPA

Ženeva: European Pressphoto Agency (EPA)

Podaci o skupu

27th Annual Conference of European Prosthodontic Association

predavanje

04.09.2003-06.09.2003

Ženeva, Švicarska

Povezanost rada

Dentalna medicina