Design, commissioning and performance of the PIBETA detector at PSI (CROSBI ID 106413)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Frlez, E. ; Pocanic, D. ; Assamagan, K.A. ; Bagaturia, Yu. ; Baranov, V.A. ; Bertl, W. ; Bronnimann, Ch. ; Bychkov, M. ; Crawford, J.F. ; Daum, M. ; Flugel, Th. ; Frosch, R. ; Horisberger, R. ; Kalinnikov, V.A. ; Karpukhin, V.V. ; Khomutov, N.V. ; Koglin, J.E. ; Korenchenko, A.S. ; Korenchenko, S.M. ; Kozlowski, T. ; Krause, B. ; Kravchuk, N.P. ; Kuchinsky, N.A. ; Li, W. ; Lawrence, D.W. ; Minehart, R.C. ; Mzhavia, D. ; Obermeier, H. ; Renker, D. ; Ritchie, B.G. ; Ritt, S. ; Sakhelashvili, T. ; Schnyder, R. ; Sidorkin, V.V. ; Slocum, P.L. ; Smith, L.C. ; Soić, Neven ; Stephens, W.A. ; Supek, Ivan ; Tsamalaidze, Z. ; VanDevender, B.A. ; Wang, Y. ; Wirtz H.P. ; Ziock K.O.H.
engleski
Design, commissioning and performance of the PIBETA detector at PSI
We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+→ pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering ~3pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure, which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two 3-month beam periods in 1999/2000 with pi+ stopping rates between 1.3· ; ; ; 103 pi+/s and 1.3· ; ; ; 106 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5 - 150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.
Large acceptance segmented calorimeter; Pure CsI scintillators; Tracking and particle identification; Detector design; construction; calibration and performance
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
526 (3)
2004.
300-347-x
objavljeno
0168-9002