Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Testing of Hydrodesulfurization Process in small Trickle-bed Reactor (CROSBI ID 106501)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Sertić-Bionda, Katica ; Gomzi, Zoran ; Šarić, Tomislav Testing of Hydrodesulfurization Process in small Trickle-bed Reactor // Chemical engineering journal, 106 (2005), 2; 105-110-x

Podaci o odgovornosti

Sertić-Bionda, Katica ; Gomzi, Zoran ; Šarić, Tomislav

engleski

Testing of Hydrodesulfurization Process in small Trickle-bed Reactor

The influence of some reaction parameters on hydrodesulfurization in the experimental trickle-bed reactor (Andreas - Hoffer apparatus) was investigated. A mixture of two gas oils (atmospheric gas oil and light cyclic oil from FCC) was used as feed. The investigations were performed at 300 0C , under space velocity from 1.0 to 2.5 h-1, hydrogen pressure of 40 and 65 bar, at H2/CH ratio from 100 to 500. A simple reactor and a kinetic model were used, yielding good agreement between experimental and theoretical values of sulfur concentrations. Simulation experiments were performed by changing H2/CH ratio and LHSV. The correlation recorded between the changed parameters and sulfur content was in that with higher temperature, pressure and ratio of H2/CH the percentage of removed sulfur increased. Increased space velocity produced opposite effect. These experimental results and the change of either one or more process parameters or of the catalyst type enabled performance of the industrial reactor.

Hydrodesulfurization; gas oil; process conditions.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

106 (2)

2005.

105-110-x

objavljeno

1385-8947

Povezanost rada

Kemijsko inženjerstvo

Indeksiranost