A problem of the electrochemical measurement results accuracy has appeared during a performed complex long term pilot plant investigations of the hot-dip galvanized steel pipes corro-sion in warm potable water. After a short introduction, the first part of the paper describes the pilot plant with pipe specimen assembly series. Specimens have been made of zinc, steel and hot-dip galvanised steel. The second part of the paper presents the performed electrochemical measurements without computer aids and displays an example of the obtained final results. The third part of the paper is devoted to the development of the system for the computer aided monitoring of the mixed electrode potentials and electric currents between short circuited specimens.
corrosion; electrochemical measurement; pilot plant; hot dip galvanized pipes; computer aided monitoring