Fire Resistance of Steel Structures (CROSBI ID 497547)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Boko, Ivica ; Peroš, Bernardin Fire Resistance of Steel Structures // Proceedings of the Second International Conference on Steel & Composite Structures, ICSCS'04 / Chang-Koon, Choi ; Hwan-Woo, Lee ; Hyo-Gyong, Kwak (ur.). Seoul: Techno-Press, 2004

Podaci o odgovornosti

Boko, Ivica ; Peroš, Bernardin

engleski

Fire Resistance of Steel Structures

Fire resistance of load-bearing structures, particularly steel ones, is currently being investigated worldwide. For determining of safety of steel structure exposed to fire, as random accidental action, it is possible to use only probabilistic methods, together with adequately laboratory researches. The procedure for determining the safety of the load-bearing structures consists of four steps. The first step includes the determination of heat action in case of fire. The next step includes the determination of heat action upon the structure. Heating the structure brings about two effects: the elongation of the structure and the degradation of the mechanical properties of the material. This step is at the same time a third step in determining the safety of the load-bearing structures. Mechanical characteristics of the raw material are get by tension test on high temperatures, while the element behaviour on high temperatures is determined as a part of experiments in special laboratory researches made on the real constructions. The safety of steel structures expressed by the safety index  was also analyzed for the extreme limit state and the serviceability limit state both for the combinations of permanent action and accidental fire action upon the structure, which represents the fourth phase of the process. On the basis of values for basis variables of resistance and fire action, values of safety index β will be determined, as well as degree of safety of the steel structures exposed to the fire. These investigations of the actual temperature-time parameter curves, for large compartments and different fire loads have been carried out in Croatia within the National Application Documents in the field of accidental fire action.

fire; fire resistance; steel structures

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

2004.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the Second International Conference on Steel & Composite Structures, ICSCS'04

Chang-Koon, Choi ; Hwan-Woo, Lee ; Hyo-Gyong, Kwak

Seoul: Techno-Press

Podaci o skupu

The Second International Conference on Steel & Composite Structures, ICSCS'04

predavanje

02.09.2004-04.09.2004

Seoul, Republika Koreja

Povezanost rada

Građevinarstvo