Esophagotracheal fistula after lithium disc battery ingestion successfully treated with hyperbaric oxygen therapy (CROSBI ID 106658)
Prilog u časopisu | stručni rad
Podaci o odgovornosti
Petri, Nadan M. ; Meštrović, Julije ; Andrić, Dejan ; Krželj, Vjekoslav ; Stipančević, Hrvoje
engleski
Esophagotracheal fistula after lithium disc battery ingestion successfully treated with hyperbaric oxygen therapy
We report a case of a 12 month old child who acquired an esophagotracheal fistula of 5 mm in diameter after an ingested lithium disc battery impaction. Failure to recognize foreign body on chest x-rays resulted in a delay of 28 days in establishing the diagnosis. Feeding via nasogastric tube and hyperbaric oxygen treatment(HBOT) resulted in a complete closure of the fistula after 17 HBOT 60 min sessions at 2.2 bars.
Foreign body; esophagotracheal fistula; hyperbaric oxygen