Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Fluorescent spot test screening for glucose-6-phosphate dehydrogenase deficiency in Dalmatia: The UNEPSA and CESP European Congress of Paediatrics, Rim 2000. (CROSBI ID 754632)

Druge vrste radova | ostalo

Krželj, Vjekoslav ; Balarin, Livio ; Zlodre, S. ; Terzić, Janoš ; Jakšić, Jasminka ; Marušić, Eli ; Petrić, Božidar Fluorescent spot test screening for glucose-6-phosphate dehydrogenase deficiency in Dalmatia: The UNEPSA and CESP European Congress of Paediatrics, Rim 2000. // The UNEPSA and CESP European Congress of Paediatrics, Rim 2000. 2000.

Podaci o odgovornosti

Krželj, Vjekoslav ; Balarin, Livio ; Zlodre, S. ; Terzić, Janoš ; Jakšić, Jasminka ; Marušić, Eli ; Petrić, Božidar

engleski

Fluorescent spot test screening for glucose-6-phosphate dehydrogenase deficiency in Dalmatia: The UNEPSA and CESP European Congress of Paediatrics, Rim 2000.

The objective of this study was to determine the prevalence of glucose-6-phosphate dehydrogenase (G-6-PD) deficiency among the population of the Croatian Adriatic Coast, part of the Mediterranean basin. METHODS: The fluorescent spot test was used to screen 2, 726 randomly selected high school students in the Croatian Adriatic coastal area. Fluorescence readings were performed at the beginning and at 3, 6, 10, and 25 min of incubation. Results were classified into the following three groups: bright fluorescence (BF), weak fluorescence (WF), and no fluorescence (NF). All NF and WF samples at 3 min were quantitatively measured using the spectrophotometric method. RESULTS: Twelve persons, 10 boys and 2 girls, were found to be deficient in G-6-PD, rendering a 0.44% prevalence of G-6-PD deficiency. All NF samples at fluorescent spot test were G-6-PD-deficient. WF at 3 min of the incubation period was present in 33 (1.2%) subjects, and only 2 (6%) were true positive. Fluorescence reading at 10 min of incubation omits five (41%) of the G-6-PD deficient samples. CONCLUSIONS: Prevalence of G-6-PD deficiency in the Croatian Adriatic coastal population is 0.44%. Fluorescent spot test for moderate enzyme deficiency is reliable in early fluorescence reading.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

The UNEPSA and CESP European Congress of Paediatrics, Rim 2000

2000.

nije evidentirano

objavljeno

Povezanost rada

Temeljne medicinske znanosti