Radon in Croatian spas (CROSBI ID 499662)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Radolić, Vanja ; Vuković, Branko ; Planinić, Josip
engleski
Radon in Croatian spas
There are ten thermal spas in Croatia and all of them provide health services for patients and visitors. Radon measurements were performed since there is a lack of data concerning natural radioactivity originated from radon and its short-lived progenies in such environments. The thermal water at two different sites (the indoor swimming pool with geothermal water and the spring) in each spa was sampled and radon concentrations were measured by AlphaGUARD radon measuring system. The obtained values were in the range of 0.7 to 19 Bq dm^-3 and 2 to 94 Bq dm^-3 for indoor swimming pools and springs, respectively. Integrated measurements of radon concentration in air were performed by two solid state nuclear track detectors LR-115 II (open and diffusion one) thus enabling estimation of equilibrium factor between radon and its daughters. The annual effective doses received by spa workers were found to be about 1 mSv/y (below the lower limit value of 3 mSv/y recommended by ICRP 65). The doses of patients and visitors were one or two order of magnitude lower than that of the personnel.
radon ; spa ; dose equivalent
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
36010913
2004.
objavljeno
Podaci o matičnoj publikaciji
Berka, Zdenek
Prag:
Podaci o skupu
4th European Conference on Protection against Radon at Home and at Work
predavanje
28.06.2004-02.07.2004
Prag, Češka Republika