Different Levels of Power Switch Modelling Depth with SIMPLORER (CROSBI ID 467185)

Prilog sa skupa u zborniku | stručni rad | međunarodna recenzija

Jakopović, Željko Different Levels of Power Switch Modelling Depth with SIMPLORER // Simulation komplexer Systeme aus der Mikrosystemtechnik, Leistungselektronik und Antriebstechnik / Knorr U. (ur.). Chemnitz: SIMEC Gmbh, TU Chemnitz, 1998. str. 75-83.-x

Podaci o odgovornosti

Jakopović, Željko

engleski

Different Levels of Power Switch Modelling Depth with SIMPLORER

Behaviour of power electronic circuits can be simulated at different complexity and accuracy levels, depending on the aim of simulation and used component models in circuit simulator. Simulation of power electronic circuits is required in analysis and design process, as well as in the education of Power electronics. For fast introduction into power circuit behaviour it is not necessary to use complex model of power electronic switch (IGBT, SCR etc.). Simple, ideal switch model will do. Also at the system level investigation it is often adequate to represent power switch within converter by more or less ideal switch. Going deeper into converter, e.g. when exact dissipation on power switches of converter is needed, more complex models of power switches are required, describing accurately voltage-current relations in power electronic switch during conduction, turn-on and turn-of. Simulator of power electronic circuits and systems should be able to provide the user wide choice of power switch complexity levels. It is on the user to choose appropriate model for his simulation task. The aim of the paper is comparative description of power switch model that can be used in SIMPLORER, with benchmark tests performed on simple chopper model. Speed of simulation and quantity and accuracy of obtained information are compared.

modeling; power electronic switch

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

75-83.-x.

1998.

objavljeno

Podaci o matičnoj publikaciji

Simulation komplexer Systeme aus der Mikrosystemtechnik, Leistungselektronik und Antriebstechnik

Knorr U.

Chemnitz: SIMEC Gmbh, TU Chemnitz

Podaci o skupu

Workshop : Simulation komplexer Systeme aus der Mikrosystemtechnik, Leistungselektronik und Antriebstechnik

predavanje

25.06.1998-26.06.1998

Chemnitz, Njemačka

Povezanost rada

Elektrotehnika