Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Influence of the concentration of ions and foramen diameter on the accuracy of electronic root canal length measurement - an experimental study (CROSBI ID 81464)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kovačević, Maja ; Tamarut, Tomislav Influence of the concentration of ions and foramen diameter on the accuracy of electronic root canal length measurement - an experimental study // Journal of endodontics, 24 (1998), 5; 346-351-x

Podaci o odgovornosti

Kovačević, Maja ; Tamarut, Tomislav

engleski

Influence of the concentration of ions and foramen diameter on the accuracy of electronic root canal length measurement - an experimental study

Investigations on the concentration of cations in human pulp have shown that pathological changes in the pulp lead to changes in the concentration of ions in the tissue. Consequently its electrophysiological characteristics are changed, which affects the accuracy of electronic root canal length measurements (ERCLM). The aim of this study was to examine the effect of concentrations of Na+, K+ and Ca++ cations in a medium within the canal and around the tooth, and also foramen diameter, on the accuracy of ERCLM. The model comprised 21 extracted single rooted human teeth, divided into two experimental and one control group, of 7 teeth each. Two aqueous solutions of different concentrations of NaCl, KCl and CaCl2 were mixed with agar. The concentrations of Na+, K+ and Ca++ corresponded to the results of analyses performed by atomic spectrophotometry on the extirpated human pulp. Agar was injected into the root canal prepared with a foramen diameter of 0.25 mm. In the control group the teeth were then completely immersed in agar of the same concentration of cations as the agar inside the canal. In the first experimental group (Group 1) the concentration of ions was higher inside the canal compared to the concentration outside the canal. In the second experimental group (Group 2) the order of concentrations was inverse. In all three groups ERCLM was first performed in the above model, after which foramens were enlarged and ERCLM repeated at 0.45 mm and 0.70 diameter respectively. The results indicate that at 0.25 diameter the most accurate measurements were taken when the concentrations of ions inside the canal were higher than outside the canal ( dif = 1.39 &#61617; 1.21 mm) (Group 1). At diameters of 0.45 and 0.70 mm no significant differences were found (p<0.05) between the experimental groups, error amounted to dif = 6.27 &#61617; 1.47 mm. In the control group measurement error increased with enlargement of the foramen.

electroodontometry; dental pulp; cations; apical foramen

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

24 (5)

1998.

346-351-x

objavljeno

0099-2399

Povezanost rada

Dentalna medicina

Indeksiranost