Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Direct quantification of lycopene in products derived from thermally processed tomatoes : Optothermal window as a selective, sensitive, and accurate analytical method without the need for preparatory steps (CROSBI ID 110798)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Bičanić, Dane ; Swarts, Jan ; Luterotti, Svjetlana ; Pietraperzia, Giangaetano ; Dóka, Otto ; de Rooij, Hans Direct quantification of lycopene in products derived from thermally processed tomatoes : Optothermal window as a selective, sensitive, and accurate analytical method without the need for preparatory steps // Analytical chemistry, 76 (2004), 17; 5203-5207. doi: 10.1021/ac040032v

Podaci o odgovornosti

Bičanić, Dane ; Swarts, Jan ; Luterotti, Svjetlana ; Pietraperzia, Giangaetano ; Dóka, Otto ; de Rooij, Hans

engleski

Direct quantification of lycopene in products derived from thermally processed tomatoes : Optothermal window as a selective, sensitive, and accurate analytical method without the need for preparatory steps

The concept of the optothermal window (OW) is proposed as a reliable analytical tool to rapidly determine the concentration of lycopene in a large variety of commercial tomato products in an extremely simple way (the determination is achieved without the need for pretreatment of the sample). The OW is a relative technique as the information is deduced from the calibration curve that relates the OW data (i.e., the product of the absorption coefficient beta and the thermal diffusion length mu) with the lycopene concentration obtained from spectrophotometric measurements. The accuracy of the method has been ascertained with a high correlation coefficient (R = 0.98) between the OW data and results acquired from the same samples by means of the conventional extraction spectrophotometric method. The intrinsic precision of the OW method is quite high (better than 1%), whereas the repeatability of the determination (RSD = 0.4-9.5%, n = 3-10) is comparable to that of spectrophotometry.

lycopene; tomatoe products; optothermal window; quantification

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

76 (17)

2004.

5203-5207

objavljeno

0003-2700

10.1021/ac040032v

Povezanost rada

Fizika, Kemija, Prehrambena tehnologija

Poveznice
Indeksiranost