Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Screening of Avalanche Photodiodes for the CMS ECAL (CROSBI ID 503502)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Antunović, Z. ; Britvich, I. ; Kuznetsov, A. ; Musienko, Y. ; Reuckroft, S. ; Swain, J ; Dieters, K. ; Ingram, Q. ; Renker, D. ; Sakhelashvili, T. et al. Screening of Avalanche Photodiodes for the CMS ECAL // ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS / M Barone (Demokritos Laboratory, Greece), E Borchi (Universita degli Studi di Firenze, Italy), C Leroy (University of Montreal, Canada), P-G Rancoita (INFN-Milano, Italy), P-L Riboni (ETH-Z, Switzerland) & R Ruchti (University of Notre Dame, USA) (ur.). Singapur: World Scientific Publishing, 2004. str. 169-175-x

Podaci o odgovornosti

Antunović, Z. ; Britvich, I. ; Kuznetsov, A. ; Musienko, Y. ; Reuckroft, S. ; Swain, J ; Dieters, K. ; Ingram, Q. ; Renker, D. ; Sakhelashvili, T. ; Godinović, N. ; Puljak, I. ; Sorić, I. ; Rusack R. ; Singovski, A.

engleski

Screening of Avalanche Photodiodes for the CMS ECAL

The Compact Muon Solenoid is one of two general purpose detectors currently being constructed for the Large Hadron Collider at CERN foreseen to begin data taking in 2007. Avalanche Photo Diodes (APDs) have been chosen to detect the scintillation light of the 61 200 lead tungstate crystals in the barrel part of the electromagnetic calorimeter of CMS. After a 8 years long R&D work Hamamatsu Photonics produces now APDs with a structure that is basically radiation resistant. Since a reliability of 99.9% is required, a method to detect weak APDs before they are built into the detector had to be developed. The described screening method is a combination of an irradiation with 60Co and annealing under bias of all APDs and on a sampling basis only an irradiation with hadrons.

APD; CMS; screening

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

169-175-x.

2004.

objavljeno

Podaci o matičnoj publikaciji

M Barone (Demokritos Laboratory, Greece), E Borchi (Universita degli Studi di Firenze, Italy), C Leroy (University of Montreal, Canada), P-G Rancoita (INFN-Milano, Italy), P-L Riboni (ETH-Z, Switzerland) & R Ruchti (University of Notre Dame, USA)

Singapur: World Scientific Publishing

Podaci o skupu

Nepoznat skup

predavanje

29.02.1904-29.02.2096

Povezanost rada

Filologija