Zona nadzora oko rendgen uređaja za kontrolu putničke prtljage i pošiljaka (CROSBI ID 504711)
Prilog sa skupa u zborniku | izvorni znanstveni rad | domaća recenzija
Podaci o odgovornosti
Prlić, Ivica ; Milković-Kraus, Sanja ; Cerovac, Zdravko
hrvatski
Zona nadzora oko rendgen uređaja za kontrolu putničke prtljage i pošiljaka
The importance of prompt occupational dose reporting rises when dose is received within short-time interval or when the radiation source suffers any technical failures. Radiation exposure is to be recognized as a private/or group hazard of each person alone. Actual radiation quality of the source is to be taken into account. To optimize the radiological radiation protection Quality Control measurements of the source are done. We have developed digital dosemeters of type “ ALARA OD2” for external dosimetry to be used for establishing the real pattern of occupational dose delivered to the workers or/and as the (Ort) professional environmental measuring station. We are using dosemeter to define the ccontrol areas and areas of concern - point (Ort) around the source. This upgrade to legal obligatory external (film badge) dosimetry will help us to ease defining the professional stuff and working places which are actually exposed to ionising radiation of concern and for which it is necessary to provide legally required, or even additional, occupational health care programme. This means the analysis of exposure situations for specific jobs near the x-ray equipment used for baggage control in the context of carrying out a detailed study for the optimisation of radiation protection. PC data readout from device forms a real time exposure dose rate pattern that proves that any worker or other employee working nearby the baggage x-ray unit is not obliged to undergo any legal occupational monitoring ( dosimetry or health) hence the total dose per year will not exceed 1 mSv under the worst working conditions.
zaštita od zračenja; medicina rada; digitalni dozimetar; područje nadzora
nije evidentirano
engleski
RADIATION PROTECTION CONTROL AREA AROUND BAGGAGE CONTROL X-RAY UNITS
nije evidentirano
radiation protection. Occupational Health; digital dosemeter; controlled area
nije evidentirano
Podaci o prilogu
197-202-x.
2003.
objavljeno
Podaci o matičnoj publikaciji
Zbornik radova petog simpozija Hrvatskog društva za zaštitu od zračenja s međunarodnim sudjelovanjem
Krajcar Bronić, I. ; Miljanić, S. ; Obelić, B.
Zagreb: Hrvatsko društvo za zaštitu od zračenja
Podaci o skupu
V simpozij HDZZZ
predavanje
09.04.2003-11.04.2003
Stubičke Toplice, Hrvatska