Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Current and Voltage WaveformsS upon the Conductor Rupture in one Phase of the 110 KV Radical Cunnection of the Generator at HPP Dubriovnik to the Ppwer System - Simulation and Measurement (CROSBI ID 504858)

Prilog sa skupa u zborniku | stručni rad | međunarodna recenzija

Stojsavljević, Milan ; Nemec, Darko ; Mehmedović, Muharem ; Čerina, Zdeslav ; Kosor, Robert ; Gazzari, Sergio Current and Voltage WaveformsS upon the Conductor Rupture in one Phase of the 110 KV Radical Cunnection of the Generator at HPP Dubriovnik to the Ppwer System - Simulation and Measurement // Proceedings of the 13th International Conference on Power System Protection (PSP 2002) / Curk, Jurij ; Gubina, Ferdinand (ur.). Ljubljana: Fakulteta za elektrotehniko, Univerza v Ljubljani, 2002

Podaci o odgovornosti

Stojsavljević, Milan ; Nemec, Darko ; Mehmedović, Muharem ; Čerina, Zdeslav ; Kosor, Robert ; Gazzari, Sergio

engleski

Current and Voltage WaveformsS upon the Conductor Rupture in one Phase of the 110 KV Radical Cunnection of the Generator at HPP Dubriovnik to the Ppwer System - Simulation and Measurement

This paper presents results of time-domain simulation of single-phase opening (the effect of the 110 kV phase conductor rupture) of the 110 kV transmission line Komolac - Trebinje (a part of radial connection of HPP Dubrovnik to the system) in realistic operating conditions. The simulation results comprise instantaneous and RMS values of phase currents, phase voltages and residual current in the 110 kV line bay Komolac at the HPP Dubrovnik switchyard and in the 110 kV transmission line bay Trebinje at the substation Komolac. Simulation results are compared with quantities recorded by the numerical line protection device REL511 installed at HPP Dubrovnik. Simulation includes electromechanical transients with excitation system and turbine governor being modelled. Rather good correspondence between simulation results and measurements in this particular case shows that such calculation results could be used as a basis for tuning and coordination of protection systems

electric power system; generator; radial connection; protection system; simulation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

2002.

objavljeno

Podaci o matičnoj publikaciji

Curk, Jurij ; Gubina, Ferdinand

Ljubljana: Fakulteta za elektrotehniko, Univerza v Ljubljani

961-6371-35-5

Podaci o skupu

International Conference on Power System Protection Conference (13 ; 2002)

predavanje

25.09.2002-27.09.2002

Bled, Slovenija

Povezanost rada

Elektrotehnika